Chapter 7 Servo Parameters
Revision June 2010
7-83
Display Format: Decimal
Settings:
In speed mode, the users can use this parameter to add an offset value to analog
speed input.
P4 - 24
LVL
Undervoltage Error Level
Address: 0430H, 0431H
Default: 160
Related Section: N/A
Applicable Control Mode: ALL
Unit: V (rms)
Range: 140 ~ 190
Data Size: 16-bit
Display Format: Decimal
Settings:
When DC Bus voltage is lower than the value of P4-24 x
2
, the fault, Undervoltage
will occur.