Chapter 2 Installation and Storage
2-14
Revision June 2010
The users can select the adequate regenerative resistors according to the allowable
frequency by referring to the table below:
Allowable Frequencies for Servo Motor Running Without Load (times/min)
When Using External Regenerative Resistor
ECMA
C
100W 200W
400W
(F60)
400W
(F80)
750W 1.0kW 2.0kW
Motor Capacity
Delta External
Regenerative Resistor
01
02
04
04
07
10
20
BR400W040 (400W 40
Ω
)
- -
8608
3506
2110 925 562
BR1K0W020 (1kW 20
Ω
)
- - -
8765
5274 2312 1406
ECMA
E
0.5kW
1kW
1.5kW
2.0kW
2.0kW
3.0kW
Motor Capacity
Delta External
Regenerative Resistor
05
1.0
15
20
20
30
BR400W040 (400W 40
Ω
)
291 283 213
163
(F130)
68
(F180)
-
BR1K0W020 (1kW 20
Ω
)
729 708 533 408 171 -
BR3K0W010 (1kW 10
Ω
)
- - - - -
331
ECMA
G
0.3kW
0.6kW
0.9kW
Motor Capacity
Delta External
Regenerative Resistor
03
06
09
BR400W040 (400W 40
Ω
)
292 283 213
BR1K0W020 (1kW 20
Ω
)
729 708 533
( ) : motor frame size, unit is in millimeters.
When the regenerative resistor capacity is not enough, the users can connect to multiple
the same capacity regenerative resistors in parallel to increase it.
Summary of Contents for ASD-B2-0121-B
Page 1: ......
Page 13: ...Table of Contents xii Revision June 2010 This page intentionally left blank...
Page 17: ...Chapter 1 Unpacking Check and Model Explanation 1 4 Revision June 2010 ECMA Series Servo Motor...
Page 87: ...Chapter 4 Display and Operation 4 12 Revision June 2010 This page intentionally left blank...
Page 131: ...Chapter 6 Control Modes of Operation 6 22 Revision June 2010 Time Domain...
Page 267: ...Chapter 8 MODBUS Communications 8 18 Revision June 2010 This page intentionally left blank...
Page 271: ...Chapter 9 Maintenance and Inspection 9 4 Revision June 2010 This page intentionally left blank...
Page 291: ...Chapter 11 Specifications 11 8 Revision June 2010 11 3 Servo Motor Speed Torque Curves...