6.3.7 Resonance Suppression
The resonance of mechanical system may occur due to excessive system stiffness or
frequency response. However, this kind of resonance condition can be improved,
suppressed, even can be eliminated by using low-pass filter (parameter P2-25) and notch
filter (parameter P2-23, P2-24) without changing control parameter.
Relevant parameters:
P2 - 23
NCF1
Notch Filter 1 (Resonance Suppression)
Communication Addr.:
022EH, 022FH
Default: 1000
Related Section:
Applicable Control Mode: ALL
Section 6.3.7
Unit: Hz
Range: 50 ~ 2000
Data Size: 16-bit
Display Format: DEC
Settings:
This parameter is used to set first resonance frequency of mechanical system. It
can be used to suppress the resonance of mechanical system and reduce the
vibration of mechanical system.
If P2-24 is set to 0, this parameter is disabled.
The parameters P2-23 and P2-24 are the first group of notch filter parameters and
the parameters P2-43 and P2-44 are the second group of notch filter parameters.
P2 - 24
DPH1
Notch Filter Attenuation Rate 1
(Resonance Suppression)
Communication Addr.:
0230H, 0231H
Default: 0
Related Section:
Applicable Control Mode: ALL
Section 6.3.7
Unit: dB
Range: 0 ~ 32
Data Size: 16-bit
Display Format: DEC
Settings: 0: Disabled
This parameter is used to set magnitude of the resonance suppression that is set
by parameter P2-23. If P2-24 is set to 0, the parameters P2-23 and P2-24 are both
disabled.
The parameters P2-23 and P2-24 are the first group of notch filter parameters and
the parameters P2-43 and P2-44 are the second group of notch filter parameters.
Summary of Contents for ASD-B2-0121-B
Page 1: ......
Page 13: ...Table of Contents xii Revision June 2010 This page intentionally left blank...
Page 17: ...Chapter 1 Unpacking Check and Model Explanation 1 4 Revision June 2010 ECMA Series Servo Motor...
Page 87: ...Chapter 4 Display and Operation 4 12 Revision June 2010 This page intentionally left blank...
Page 131: ...Chapter 6 Control Modes of Operation 6 22 Revision June 2010 Time Domain...
Page 267: ...Chapter 8 MODBUS Communications 8 18 Revision June 2010 This page intentionally left blank...
Page 271: ...Chapter 9 Maintenance and Inspection 9 4 Revision June 2010 This page intentionally left blank...
Page 291: ...Chapter 11 Specifications 11 8 Revision June 2010 11 3 Servo Motor Speed Torque Curves...