Chapter 6 Control Modes of Operation
Revision June 2010
6-15
Total acceleration time = TACC + TSL
Total deceleration time = TDEC + TSL
The functions of parameters P1-34, P1-35 and P1-36 are each individual. When P1-
36 is set to 0 (Disabled), the settings of P1-34, P1-35 are still effective. It indicates
that the parameters P1-34 and P1-35 will not become disabled even when P1-36 is
disabled.
NOTE
1.
When the source of speed command is analog command, the maximum setting
value of P1-36 is set to 0, the acceleration and deceleration function will be disabled.
2.
When the source of speed command is analog command, the maximum setting
value of P1-36 is limited to 10000 automatically.
Analog Speed Command S-curve Filter
ASDA-B2 series servo drives also provide Analog Speed Command S-curve Filter for the
smoothing in response to a sudden analog input signal.
Speed (rpm)
3000
-3000
0
1
3
2
4
6
5
7
9
8
Time (sec)
Motor Torque
Analog speed command
The analog speed command S-curve filter is for the smoothing of analog input signal and
its function is the same as the S-curve filter. The speed and acceleration curve of analog
speed command S-curve filter are both continuous. The above figure shows the curve of
analog speed command S-curve filter and the users can see the ramp of speed command
is different during acceleration and deceleration. Also, the users can see the difference of
input command tracking and can adjust time setting by using parameter P1-34, P1-35, P1-
36 to improve the actual motor performance according to actual condition.
Analog Speed Command Low-pass Filter
Analog Speed Command Low-pass Filter is used to eliminate high frequency response and
electrical interference from an analog speed command and it is also with smoothing
function.
Summary of Contents for ASD-B2-0121-B
Page 1: ......
Page 13: ...Table of Contents xii Revision June 2010 This page intentionally left blank...
Page 17: ...Chapter 1 Unpacking Check and Model Explanation 1 4 Revision June 2010 ECMA Series Servo Motor...
Page 87: ...Chapter 4 Display and Operation 4 12 Revision June 2010 This page intentionally left blank...
Page 131: ...Chapter 6 Control Modes of Operation 6 22 Revision June 2010 Time Domain...
Page 267: ...Chapter 8 MODBUS Communications 8 18 Revision June 2010 This page intentionally left blank...
Page 271: ...Chapter 9 Maintenance and Inspection 9 4 Revision June 2010 This page intentionally left blank...
Page 291: ...Chapter 11 Specifications 11 8 Revision June 2010 11 3 Servo Motor Speed Torque Curves...