Chapter 7 Servo Parameters
7-68
Revision June 2010
P2 - 67
JSL
Stable Inertia Estimating Time
Address: 0286H, 0287H
Default: 1.5
Related Section: N/A
Applicable Control Mode: ALL
Unit: 0.1times
Range: 0 ~ 200.0
Data Size: 16-bit
Display Format: Decimal
Settings:
In semi-auto tuning mode, after the servo drive continuously perform the
adjustment for a period of time which is determined by P2-67, the system will
consider that the system inertia has become stable and finish the operation of
system inertia estimation.