Chapter 7 Servo Parameters
Revision June 2010
7-73
The monitor data can be displayed on PC upon the data scope function provided
by ASDA-Soft software.
Byte
-
-
Low
High
Function -
-
Monitor
mode
Range
0 0 0 0
~
3
H: Monitor mode, the value must be within the range from 0 through 3.
0: Disabled, i.e. disable monitor function.
1: Reserved.
2: High-speed monitor mode. The sampling time is 2000 times per second and 4
channels can be monitored.
3: High-speed monitor mode. The sampling time is 4000 times per second and 2
channels can be monitored.
P3 - 09
Reserved (Do Not Use)
P3 - 10
Reserved (Do Not Use)
P3 - 11
Reserved (Do Not Use)