Chapter 7 Servo Parameters
7-88
Revision June 2010
Setting value: 0x25
DI Name
DI Function Description
Trigger
Method
Control
Mode
TLLM
Torque limit - Reverse operation (Torque limit
function is valid only when P1-02 is enabled)
Level
Triggered
PT, S
Setting value: 0x26
DI Name
DI Function Description
Trigger
Method
Control
Mode
TRLM
Torque limit - Forward operation (Torque limit
function is valid only when P1-02 is enabled)
Level
Triggered
PT, S
Setting value: 0x37
DI Name
DI Function Description
Trigger
Method
Control
Mode
JOGU
Forward JOG input. When JOGU is activated, the
motor will JOG in forward direction. [see P4-05]
Level
Triggered
All
Setting value: 0x38
DI Name
DI Function Description
Trigger
Method
Control
Mode
JOGD
Reverse JOG input. When JOGD is activated, the motor
will JOG in reverse direction. [see P4-05]
Level
Triggered
All
Setting value: 0x43, 0x44
DI Name
DI Function Description
Trigger
Method
Control
Mode
GNUM0
GNUM1
Electronic gear ratio (Numerator) selection 0 ~ 1 [see
P2-60 ~ P2-62]
Level
Triggered
PT
Summary of Contents for ASD-B2-0121-B
Page 1: ......
Page 13: ...Table of Contents xii Revision June 2010 This page intentionally left blank...
Page 17: ...Chapter 1 Unpacking Check and Model Explanation 1 4 Revision June 2010 ECMA Series Servo Motor...
Page 87: ...Chapter 4 Display and Operation 4 12 Revision June 2010 This page intentionally left blank...
Page 131: ...Chapter 6 Control Modes of Operation 6 22 Revision June 2010 Time Domain...
Page 267: ...Chapter 8 MODBUS Communications 8 18 Revision June 2010 This page intentionally left blank...
Page 271: ...Chapter 9 Maintenance and Inspection 9 4 Revision June 2010 This page intentionally left blank...
Page 291: ...Chapter 11 Specifications 11 8 Revision June 2010 11 3 Servo Motor Speed Torque Curves...