Chapter 6 Control Modes of Operation
Revision June 2010
6-39
P1 - 03
AOUT Pulse Output Polarity Setting
Communication Addr.:
0106H, 0107H
Default: 0
Related Section:
Applicable Control Mode: ALL
Section 3.3.3
Unit: N/A
Range: 0 ~ 3
Data Size: 16-bit
Display Format: HEX
Settings:
not used
A
B
Monitor analog output polarity
•
A=0: MON1(+), MON2(+)
•
A=1: MON1(+), MON2(-)
•
A=2: MON1(-), MON2(+)
•
A=3: MON1(-), MON2(-)
Pulse output polarity
•
B=0: Forward output
•
B=1: Reverse output
P1 - 04
MON1 Analog Monitor Output Proportion 1(CH1)
Communication Addr.:
0108H, 0109H
Default: 100
Related Section:
Applicable Control Mode: ALL
Section 6.4.4
Unit: % (full scale)
Range: 0 ~ 100
Data Size: 16-bit
Display Format: DEC
P1 - 05
MON2 Analog Monitor Output Proportion 2(CH2)
Communication Addr.:
0108H, 0109H
Default: 100
Related Section:
Applicable Control Mode: ALL
Section 6.4.4
Unit: % (full scale)
Range: 0~100
Data Size: 16-bit
Display Format: DEC
Summary of Contents for ASD-B2-0121-B
Page 1: ......
Page 13: ...Table of Contents xii Revision June 2010 This page intentionally left blank...
Page 17: ...Chapter 1 Unpacking Check and Model Explanation 1 4 Revision June 2010 ECMA Series Servo Motor...
Page 87: ...Chapter 4 Display and Operation 4 12 Revision June 2010 This page intentionally left blank...
Page 131: ...Chapter 6 Control Modes of Operation 6 22 Revision June 2010 Time Domain...
Page 267: ...Chapter 8 MODBUS Communications 8 18 Revision June 2010 This page intentionally left blank...
Page 271: ...Chapter 9 Maintenance and Inspection 9 4 Revision June 2010 This page intentionally left blank...
Page 291: ...Chapter 11 Specifications 11 8 Revision June 2010 11 3 Servo Motor Speed Torque Curves...