Chapter 6 Control Modes of Operation
Revision June 2010
6-13
Relevant parameters:
P1 - 34
TACC Acceleration Time
Communication Addr.:
00144H, 0145H
Default: 200
Related Section:
Applicable Control Mode: S
Section 6.3.3
Unit: ms
Range: 1 ~ 20000
Data Size: 16-bit
Display Format: DEC
Settings:
This parameter is used to determine the acceleration time to accelerate from 0 to
its rated motor speed. The functions of parameters P1-34, P1-35 and P1-36 are
each individual. When P1-36 is set to 0 (Disabled), the settings of P1-34, P1-35 are
still effective. It indicates that the parameters P1-34 and P1-35 will not become
disabled even when P1-36 is disabled.
NOTE
1.
When the source of speed command is analog command, the maximum setting
value of P1-36 is set to 0, the acceleration and deceleration function will be disabled.
2.
When the source of speed command is analog command, the maximum setting
value of P1-34 is limited to 20000 automatically.
Summary of Contents for ASD-B2-0121-B
Page 1: ......
Page 13: ...Table of Contents xii Revision June 2010 This page intentionally left blank...
Page 17: ...Chapter 1 Unpacking Check and Model Explanation 1 4 Revision June 2010 ECMA Series Servo Motor...
Page 87: ...Chapter 4 Display and Operation 4 12 Revision June 2010 This page intentionally left blank...
Page 131: ...Chapter 6 Control Modes of Operation 6 22 Revision June 2010 Time Domain...
Page 267: ...Chapter 8 MODBUS Communications 8 18 Revision June 2010 This page intentionally left blank...
Page 271: ...Chapter 9 Maintenance and Inspection 9 4 Revision June 2010 This page intentionally left blank...
Page 291: ...Chapter 11 Specifications 11 8 Revision June 2010 11 3 Servo Motor Speed Torque Curves...