8. Specifications and test methods
8.5 Performance characteristics test
666
b)
Testing block diagram and testing instrument and equipment
Synthesized signal generator (E8257D/1464 is recommended)
2434/E4418B is recommended for the power meter.
71712A/N8487A is recommended for the power sensor.
11667C is recommended for the power divider.
c)
Test steps
Frequency response: (50MHz ~ 4GHz)
1)
Connect the tested instrument as shown in Fig. 8.9.
2)
Set the output frequency of the synthesized signal generator as 50 MHz, the frequency step as 200 MHz
and the amplitude as -4 dBm.
3)
Reset and set the 4051 analyzer:
Center frequency:
..................................................................................................
50MHz
Span:
............................................................................................................................
0Hz
Resolution bandwidth:
...........................................................................................
300kHz
Video bandwidth:
....................................................................................................
30kHz
Frequency step:
...................................................................................................
200 MHz
In case of frequency less than 1.1GHz, set the phase noise optimization Off
(【
Measurement Setting
】、
[More 1/2
▶
] [PhNoise Opt >>] [off]
)。
Set as Off when the pre-amplifier option is provided.
4)
Set the power meter frequency as 50 MHz.
5)
Record the 4051 marker reading L
2
and the power meter reading L
1
in the 4051 Auxiliary Form.
6)
Execute Frequency Step Up for the synthesized signal generator and the 4051 analyzer.
7)
Repeat the power meter frequency as the frequency value to be tested next in B8 of the 4051 Auxiliary
Form and repeat step 5 to 6 for each frequency point in the 4051 Auxiliary Form.
Frequency response: (4GHz
~
9GHz)
8)
Set the output frequency of the synthesized signal generator as 4.05 GHz and the center frequency of the
4051 analyzer as 4.05 GHz.
9)
Set the power meter frequency as 4.05GHz.
10)
Record the 4051 marker reading L
2
and the power meter reading L
1
in the 4051 Auxiliary Form.
11)
Execute Frequency Step Up for the synthesized signal generator and the 4051 analyzer.
12)
Repeat the power meter frequency as the frequency value to be tested next in B8 of the 4051 Auxiliary
Form and repeat step 10 to 11 for each frequency point in the 4051 Auxiliary Form.
Summary of Contents for 4051 Series
Page 5: ......
Page 6: ......
Page 7: ......
Page 14: ......
Page 18: ......
Page 68: ......
Page 225: ...5 Menu 5 1 Menu structure 211 5 1 3 13 Maker Mkr Fig 5 3 13 Marker Menu...
Page 241: ...5 Menu 5 1 Menu structure 227 5 1 4 13 Maker Mkr Fig 5 4 13 Marker Menu...
Page 259: ...5 Menu 5 1 Menu structure 245 5 1 5 13 Maker Mkr Fig 5 5 13 Marker Menu...
Page 266: ...5 Menu 5 1 Menu structure 252 5 1 6 5 Sweep Sweep Fig 5 6 5 Sweep Menu...
Page 275: ...5 Menu 5 1 Menu structure 261 5 1 6 13 Maker Mkr Fig 5 6 13 Marker Menu...
Page 277: ...5 Menu 5 1 Menu structure 263 5 1 6 15 Peak Search Peak Search Fig 5 6 15 Peak Search Menu...
Page 280: ...5 Menu 5 1 Menu structure 266 5 1 7 3 Span X Scale Span Fig 5 7 3 Span Menu...
Page 291: ...5 Menu 5 1 Menu structure 277 5 1 7 13 Maker Mkr Fig 5 7 13 Marker Menu...
Page 296: ...5 Menu 5 1 Menu structure 282 5 1 8 3 Span X Scale Span Fig 5 8 3 Span Menu...
Page 306: ...5 Menu 5 1 Menu structure 292 5 1 8 12 Marker Marker Fig 5 8 12 Marker Menu...
Page 307: ...5 Menu 5 1 Menu structure 293 5 1 8 13 Maker Mkr Fig 5 8 13 Marker Menu...
Page 309: ...5 Menu 5 1 Menu structure 295 5 1 8 15 Peak Search Peak Search Fig 5 8 15 Peak Search Menu...
Page 312: ...5 Menu 5 1 Menu structure 298 5 1 9 3 Span X Scale Span Span 4 000000 GHz Fig 5 9 3 Span Menu...
Page 323: ...5 Menu 5 1 Menu structure 309 5 1 9 13 Maker Mkr Fig 5 9 13 Marker Menu...
Page 328: ...5 Menu 5 1 Menu structure 314 5 1 10 3 Span X Scale Span Fig 5 10 3 Span Menu...
Page 329: ...5 Menu 5 1 Menu structure 315 5 1 10 4 Bandwidth BW Fig 5 10 4 Bandwidth Menu...
Page 333: ...5 Menu 5 1 Menu structure 319 5 1 10 7 Trace Trace Fig 5 10 7 Trace Menu...
Page 340: ...5 Menu 5 1 Menu structure 326 5 1 10 13 Maker Mkr Fig 5 10 13 Marker Menu...
Page 345: ...5 Menu 5 1 Menu structure 331 5 1 11 3 Span X Scale Span Fig 5 11 3 Span Menu...
Page 357: ...5 Menu 5 1 Menu structure 343 5 1 11 13 Maker Mkr Fig 5 11 13 Marker Menu...
Page 359: ...5 Menu 5 1 Menu structure 345 5 1 11 15 Peak Search Peak Search Fig 5 11 15 Peak Search Menu...
Page 656: ......