
5 Menu
5.2. Description of menu
552
●
Status saved: saved in the instrument status.
●
Factory preset: Auto
●
Setting range: -1.0E+8~, set the maximum frequency of the instrument.
●
Default unit: Hz
●
Remote Command:
[:SENSe]:TOI:FREQuency:BASE:UPPer <frequency>
[:SENSe]:TOI:FREQuency:BASE:UPPer?
[:SENSe]:TOI:FREQuency:BASE:UPPer:AUTO OFF|ON|0|1
[:SENSe]:TOI:FREQuency:BASE:UPPer:AUTO?
[CF Step Auto
Man
]
See the [CF Step Auto Man] under
【
Frequency
】
of the sweep analysis function for more details.
[Freq Offset]
See the [Freq Offset] under
【
Frequency
】
of the sweep analysis function for more details.
5.2.9.2 Ampld/YScale
Pop up More related to parameter setting of Ampld/YScale, including [RefLevel], [Attenuation
▶
],
[PreAmplifier On/Off], [Scale/Div], [Auto Scale], [More 1/2
▶
], [Y Axis Unit], [Ref Level Offset].
[RefLevel]
●
Menu description: to enable the Reference Level function. The reference level can be adjusted with the
number keys, step keys or knob. The reference level corresponds to the top of the coordinate top.
Measure signal at reference level position to get highest accuracy. The input attenuator of the
signal/spectrum analyzer is coupled to the reference level, which can be automatically changed to avoid
compression of input signal.
●
Key path:
【
Ampld/YScale
】
, [RefLevel] on the front panel.
●
Status saved: saved in the instrument status.
●
Factory preset: 0dBm
●
Setting range: Min.: -170dBm, Max.: 30dBm.
●
Default unit: set based on Y Axis scale unit.
●
Remote Command:
:DISPlay:TOI:VIEW:WINDow:TRACe:Y:RLEVel <real>
:DISPlay:TOI:VIEW:WINDow:TRACe:Y:RLEVel?
●
Examples:
:DISPl:TOI:VIEW:WINDow:TRAC:Y:RLEVel 20dBm
[Attenuation
▶
]
See [Attenuation
▶
] under
【
Ampld/YScale
】
of the sweep analysis function for more details.
Summary of Contents for 4051 Series
Page 5: ......
Page 6: ......
Page 7: ......
Page 14: ......
Page 18: ......
Page 68: ......
Page 225: ...5 Menu 5 1 Menu structure 211 5 1 3 13 Maker Mkr Fig 5 3 13 Marker Menu...
Page 241: ...5 Menu 5 1 Menu structure 227 5 1 4 13 Maker Mkr Fig 5 4 13 Marker Menu...
Page 259: ...5 Menu 5 1 Menu structure 245 5 1 5 13 Maker Mkr Fig 5 5 13 Marker Menu...
Page 266: ...5 Menu 5 1 Menu structure 252 5 1 6 5 Sweep Sweep Fig 5 6 5 Sweep Menu...
Page 275: ...5 Menu 5 1 Menu structure 261 5 1 6 13 Maker Mkr Fig 5 6 13 Marker Menu...
Page 277: ...5 Menu 5 1 Menu structure 263 5 1 6 15 Peak Search Peak Search Fig 5 6 15 Peak Search Menu...
Page 280: ...5 Menu 5 1 Menu structure 266 5 1 7 3 Span X Scale Span Fig 5 7 3 Span Menu...
Page 291: ...5 Menu 5 1 Menu structure 277 5 1 7 13 Maker Mkr Fig 5 7 13 Marker Menu...
Page 296: ...5 Menu 5 1 Menu structure 282 5 1 8 3 Span X Scale Span Fig 5 8 3 Span Menu...
Page 306: ...5 Menu 5 1 Menu structure 292 5 1 8 12 Marker Marker Fig 5 8 12 Marker Menu...
Page 307: ...5 Menu 5 1 Menu structure 293 5 1 8 13 Maker Mkr Fig 5 8 13 Marker Menu...
Page 309: ...5 Menu 5 1 Menu structure 295 5 1 8 15 Peak Search Peak Search Fig 5 8 15 Peak Search Menu...
Page 312: ...5 Menu 5 1 Menu structure 298 5 1 9 3 Span X Scale Span Span 4 000000 GHz Fig 5 9 3 Span Menu...
Page 323: ...5 Menu 5 1 Menu structure 309 5 1 9 13 Maker Mkr Fig 5 9 13 Marker Menu...
Page 328: ...5 Menu 5 1 Menu structure 314 5 1 10 3 Span X Scale Span Fig 5 10 3 Span Menu...
Page 329: ...5 Menu 5 1 Menu structure 315 5 1 10 4 Bandwidth BW Fig 5 10 4 Bandwidth Menu...
Page 333: ...5 Menu 5 1 Menu structure 319 5 1 10 7 Trace Trace Fig 5 10 7 Trace Menu...
Page 340: ...5 Menu 5 1 Menu structure 326 5 1 10 13 Maker Mkr Fig 5 10 13 Marker Menu...
Page 345: ...5 Menu 5 1 Menu structure 331 5 1 11 3 Span X Scale Span Fig 5 11 3 Span Menu...
Page 357: ...5 Menu 5 1 Menu structure 343 5 1 11 13 Maker Mkr Fig 5 11 13 Marker Menu...
Page 359: ...5 Menu 5 1 Menu structure 345 5 1 11 15 Peak Search Peak Search Fig 5 11 15 Peak Search Menu...
Page 656: ......