![Ceyear 4051 Series User Manual Download Page 362](http://html1.mh-extra.com/html/ceyear/4051-series/4051-series_user-manual_2584924362.webp)
5 Menu
5.2. Description of menu
348
[Auto
Align
On Off]
Control ON and OFF of the Auto Calibration. Under default setting, this function is ON. The signal/spectrum
analyzer will automatically judge whether to calibrate any parameters based on start-up time and internal
temperature change. When [Auto Align Man] is set as ON, automatic calibration will be taken 15 minutes
after start-up. If within 15 minutes, the instrument detects that the internal temperature change exceeds 10 °C,
the instrument will automatically stop current test and conduct auto calibration. After calibration, the
instrument will proceed measurement. For every change of 10 °C for the internal temperature, the instrument
takes one auto calibration. You can set the Auto Calibration as OFF to avoid interruption of normal
measurement by Auto Calibration. However, the measurement results may be affected if there is large internal
temperature change or the auto calibration fails to be taken for a long time.
Remote Command:
:calibration:AUTO OFF|ON
:calibration:AUTO?
Examples:
:CAL:AUTO OFF
[
Freq
Diagnose
▶
]
Display soft menus related to frequency diagnosis, including [LO Frequency], [Sample Oscillation Frequency]
and [Decimal Div Ratio].
Note: in multi-band sweep, the displayed frequency corresponds to the start frequency of the corresponding
band for which the oscillator sweeps.
This menu has no corresponding remote commands, and is mainly for local usage.
[LO Freq]
Display the start frequency of the first LO of the current band. This menu has no corresponding remote
commands, and is mainly for local usage.
[Sample
Surge Freq
]
Display the sample oscillator frequency to which the current band start frequency corresponds and the
compensation value of the sample loop bandwidth. This menu has no corresponding remote commands, and is
mainly for local usage.
[Decimal
Div Ratio
]
Display the Decimal Div Ratio to which the current band start frequency corresponds. This menu has no
corresponding remote commands, and is mainly for usage by local debugger.
[Preselector Auto Adjust]
With this menu, you can take auto calibration of the preselector center frequency to ensure accuracy and
consistency of instrument measurement. This menu has no corresponding remote commands, and is mainly
for local usage.
Summary of Contents for 4051 Series
Page 5: ......
Page 6: ......
Page 7: ......
Page 14: ......
Page 18: ......
Page 68: ......
Page 225: ...5 Menu 5 1 Menu structure 211 5 1 3 13 Maker Mkr Fig 5 3 13 Marker Menu...
Page 241: ...5 Menu 5 1 Menu structure 227 5 1 4 13 Maker Mkr Fig 5 4 13 Marker Menu...
Page 259: ...5 Menu 5 1 Menu structure 245 5 1 5 13 Maker Mkr Fig 5 5 13 Marker Menu...
Page 266: ...5 Menu 5 1 Menu structure 252 5 1 6 5 Sweep Sweep Fig 5 6 5 Sweep Menu...
Page 275: ...5 Menu 5 1 Menu structure 261 5 1 6 13 Maker Mkr Fig 5 6 13 Marker Menu...
Page 277: ...5 Menu 5 1 Menu structure 263 5 1 6 15 Peak Search Peak Search Fig 5 6 15 Peak Search Menu...
Page 280: ...5 Menu 5 1 Menu structure 266 5 1 7 3 Span X Scale Span Fig 5 7 3 Span Menu...
Page 291: ...5 Menu 5 1 Menu structure 277 5 1 7 13 Maker Mkr Fig 5 7 13 Marker Menu...
Page 296: ...5 Menu 5 1 Menu structure 282 5 1 8 3 Span X Scale Span Fig 5 8 3 Span Menu...
Page 306: ...5 Menu 5 1 Menu structure 292 5 1 8 12 Marker Marker Fig 5 8 12 Marker Menu...
Page 307: ...5 Menu 5 1 Menu structure 293 5 1 8 13 Maker Mkr Fig 5 8 13 Marker Menu...
Page 309: ...5 Menu 5 1 Menu structure 295 5 1 8 15 Peak Search Peak Search Fig 5 8 15 Peak Search Menu...
Page 312: ...5 Menu 5 1 Menu structure 298 5 1 9 3 Span X Scale Span Span 4 000000 GHz Fig 5 9 3 Span Menu...
Page 323: ...5 Menu 5 1 Menu structure 309 5 1 9 13 Maker Mkr Fig 5 9 13 Marker Menu...
Page 328: ...5 Menu 5 1 Menu structure 314 5 1 10 3 Span X Scale Span Fig 5 10 3 Span Menu...
Page 329: ...5 Menu 5 1 Menu structure 315 5 1 10 4 Bandwidth BW Fig 5 10 4 Bandwidth Menu...
Page 333: ...5 Menu 5 1 Menu structure 319 5 1 10 7 Trace Trace Fig 5 10 7 Trace Menu...
Page 340: ...5 Menu 5 1 Menu structure 326 5 1 10 13 Maker Mkr Fig 5 10 13 Marker Menu...
Page 345: ...5 Menu 5 1 Menu structure 331 5 1 11 3 Span X Scale Span Fig 5 11 3 Span Menu...
Page 357: ...5 Menu 5 1 Menu structure 343 5 1 11 13 Maker Mkr Fig 5 11 13 Marker Menu...
Page 359: ...5 Menu 5 1 Menu structure 345 5 1 11 15 Peak Search Peak Search Fig 5 11 15 Peak Search Menu...
Page 656: ......