User Manual
8
i Series / iX Series
2.1.5 DC Measurements (iX series)
Parameter
Range
Accuracy ( )
Resolution
Voltage
0
– 300 Volts
0.1 Volts
0.01 Volt
Current
0
– 40 Amps
0.01 Amps
0.001 Amp
Power
0
– 6.000 kW
0.05 kW
0.001 kW
Current and Power Accuracy specifications are times two for 10001iX and times three for 15001iX. For 10001iX and
15001iX, resolution decreases by factor of 10, ranges for current and power increases by factor of three.
2.1.6 Harmonic Measurements (iX series)
Parameter
Range
Accuracy ( )
Resolution
Frequency fundamental
16.00 - 500 Hz
0.01% + 0.01 Hz
0.01 Hz
Frequency harmonics
32.00 Hz - 19.5 kHz
2 typ.
0.5
Voltage
Fundamental
0.25V
0.01V
Harmonic 2 - 50
0.25V + 0.1% +
0.1%/kHz
0.01V
Current
Fundamental
0.05A
0.01A
Harmonic 2 - 50
0.05A + 0.1% +
0.1%/kHz
0.01A
Accuracy specifications are times three for three phase mode. Harmonics frequency range in three phase mode is
32 Hz - 6.67 kHz. Resolution decreases by factor of 10 for 10001iX and 15001iX.
2.1.7 System Specification
Parameter
Specification
External
Modulation:
0 to 10%
Synchronization
Input:
Isolated TTL input for external frequency control. Requires 5V at 5 ma
for logic high.
Trigger Output:
400 s pulse for voltage or frequency change. Isolated output that
requires a pull-up resistor, 22K , to + 5 VDC.
Non volatile
memory storage:
8 complete instrument setups and transient lists, 32 events per list.
Waveforms
Sine (i series)
Sine, square, clipped, user defined (iX series)
Summary of Contents for 10001i
Page 2: ......
Page 3: ......
Page 6: ...ii This page intentionally left blank...
Page 38: ...User Manual 24 i Series iX Series Figure 3 5 Rear Panel View for the 3001i 3001iX...
Page 39: ...User Manual i Series iX Series 25 Figure 3 6 Rear Panel View for the 5001i 5001iX...
Page 43: ...User Manual i Series iX Series 29 Figure 3 8 Functional Test Setup...
Page 44: ...User Manual 30 i Series iX Series Figure 3 9 Single Phase 10000 VA System 10001iX i...
Page 46: ...User Manual 32 i Series iX Series Figure 3 11 Single Phase 15000 VA System 15001iX i...
Page 48: ...User Manual 34 i Series iX Series Figure 3 13 Connection With MODE Option...
Page 118: ...User Manual 104 i Series iX Series Figure 5 2 Power Source Module Block Diagram...
Page 121: ...User Manual i Series iX Series 107 Figure 5 3 5001i Internal Layout...
Page 122: ...User Manual 108 i Series iX Series Figure 5 4 Logic Board LED s...
Page 124: ...User Manual 110 i Series iX Series Figure 5 5 AC Power Stage Layout...
Page 125: ...User Manual i Series iX Series 111 Figure 5 6 AC Control Logic Block Diagram...
Page 138: ...User Manual 124 i Series iX Series Figure 6 3 Adjustment Location...
Page 152: ...User Manual 138 i Series iX Series Figure 9 4 Voltage Modulation...
Page 219: ...User Manual i Series iX Series 205 Figure 9 36 Example Connection With 5001iX and EOS 1...
Page 221: ...User Manual i Series iX Series 207 Figure 9 38 15003iX CTS EOS3 LR3...
Page 222: ...User Manual 208 i Series iX Series Figure 9 39 15003iX 3 EOS3...
Page 233: ...User Manual i Series iX Series 219 Figure 9 41 Example Connection With MODE iX...
Page 240: ...User Manual 226 i Series iX Series Figure 9 42 Example Connections With OMNI 1 18i...
Page 241: ...User Manual i Series iX Series 227 Figure 9 43 Example Connections With OMNI 3 18i...