User Manual
190
i Series / iX Series
9.3.4.2 IEC GROUPS
This section will describe the groups and parameters associated with IEC 61000-4-13. Refer to
paragraph 9.3.4.1 for groups associated with the test.
FCURVE GROUP
If the FCURVE group is selected, the screen will appear as shown in Figure 9-26. The screen
has the following parameters that are unique to the group:
Figure 9-26: IEC 61000-4-13 FCurve
1. LEVEL
Set the Flat curve clip level. This field can be set when the IEC 1000-4-13 is in
the OFF state and the Class is set for USER class.
2. PAUSE
Time in seconds the test will pause prior to proceeding to the following test. This
field can be set at any time when the test is not running.
OSWING GROUP
If the OSWING group is selected, the screen will appear as shown in Figure 9-27. The screen
has the following parameters that are unique to the group:
Figure 9-27: IEC 61000-4-13 OSwing
1. LEVEL
The level of the harmonics relative to the fundamental in percent. There are
two levels, one for harmonic #3 and the other for harmonic #5. The harmonic
number must be selected prior to the harmonic level entry. To change levels,
the test state must be off and USER class must be selected.
2. HARM NO There are only two harmonic numbers. This field is used to set the harmonics
level that corresponds to the harmonics number.
3. PHASE
Sets the phase angle of the harmonics relative to the fundamental. The phase
can be set when the test state is off and USER class is selected.
4. PAUSE
Sets the time in seconds. The test will pause prior to proceeding to the
following test. This field may be changed at any time as long as the test is not
running.
Summary of Contents for 10001i
Page 2: ......
Page 3: ......
Page 6: ...ii This page intentionally left blank...
Page 38: ...User Manual 24 i Series iX Series Figure 3 5 Rear Panel View for the 3001i 3001iX...
Page 39: ...User Manual i Series iX Series 25 Figure 3 6 Rear Panel View for the 5001i 5001iX...
Page 43: ...User Manual i Series iX Series 29 Figure 3 8 Functional Test Setup...
Page 44: ...User Manual 30 i Series iX Series Figure 3 9 Single Phase 10000 VA System 10001iX i...
Page 46: ...User Manual 32 i Series iX Series Figure 3 11 Single Phase 15000 VA System 15001iX i...
Page 48: ...User Manual 34 i Series iX Series Figure 3 13 Connection With MODE Option...
Page 118: ...User Manual 104 i Series iX Series Figure 5 2 Power Source Module Block Diagram...
Page 121: ...User Manual i Series iX Series 107 Figure 5 3 5001i Internal Layout...
Page 122: ...User Manual 108 i Series iX Series Figure 5 4 Logic Board LED s...
Page 124: ...User Manual 110 i Series iX Series Figure 5 5 AC Power Stage Layout...
Page 125: ...User Manual i Series iX Series 111 Figure 5 6 AC Control Logic Block Diagram...
Page 138: ...User Manual 124 i Series iX Series Figure 6 3 Adjustment Location...
Page 152: ...User Manual 138 i Series iX Series Figure 9 4 Voltage Modulation...
Page 219: ...User Manual i Series iX Series 205 Figure 9 36 Example Connection With 5001iX and EOS 1...
Page 221: ...User Manual i Series iX Series 207 Figure 9 38 15003iX CTS EOS3 LR3...
Page 222: ...User Manual 208 i Series iX Series Figure 9 39 15003iX 3 EOS3...
Page 233: ...User Manual i Series iX Series 219 Figure 9 41 Example Connection With MODE iX...
Page 240: ...User Manual 226 i Series iX Series Figure 9 42 Example Connections With OMNI 1 18i...
Page 241: ...User Manual i Series iX Series 227 Figure 9 43 Example Connections With OMNI 3 18i...