Test No. Section
Subject
Test Limits
Comment
File Ref.
800-2 800 Hz, Negative DC Offset
115V RMS - .10 DC offset
Apply for 30 mins
FSVF108-800-2
SVF109
Normal Voltage Transients
400-1 400 Hz, Overvoltage Transients
Peak Voltage 180V RMS
Table SVF109-2
FSVF109-400-1
400-2 400 Hz, Undervoltage Transients
Low Voltage 80V RMS
Table SVF109-2
FSVF109-400-2
400-3 400 Hz, Combined Transient
180V to 80V RMS
Table SVF109-2
FSVF109-400-3
400-4 400 Hz, Repetitive Normal Voltage Transient Test
90V to 140V RMS
Figure SVF109-2
FSVF109-400-4
360-1 360 Hz, Overvoltage Transients
Peak Voltage 180V RMS
Table SVF109-2
FSVF109-360-1
360-2 360 Hz, Undervoltage Transients
Low Voltage 80V RMS
Table SVF109-2
FSVF109-360-2
360-3 360 Hz, Combined Transient
180V to 80V RMS
Table SVF109-2
FSVF109-360-3
360-4 360 Hz, Repetitive Normal Voltage Transient Test
90V to 140V RMS
Figure SVF109-2
FSVF109-360-4
600-1 600 Hz, Overvoltage Transients
Peak Voltage 180V RMS
Table SVF109-2
FSVF109-600-1
600-2 600 Hz, Undervoltage Transients
Low Voltage 80V RMS
Table SVF109-2
FSVF109-600-2
600-3 600 Hz, Combined Transient
180V to 80V RMS
Table SVF109-2
FSVF109-600-3
600-4 600 Hz, Repetitive Normal Voltage Transient Test
90V to 140V RMS
Figure SVF109-2
FSVF109-600-4
800-1 800 Hz, Overvoltage Transients
Peak Voltage 180V RMS
Table SVF109-2
FSVF109-800-1
800-2 800 Hz, Undervoltage Transients
Low Voltage 80V RMS
Table SVF109-2
FSVF109-800-2
800-3 800 Hz, Combined Transient
180V to 80V RMS
Table SVF109-2
FSVF109-800-3
800-4 800 Hz, Repetitive Normal Voltage Transient Test
90V to 140V RMS
Figure SVF109-2
FSVF109-800-4
SVF110
Normal Frequency Transients
1
Overfrequency Transients
High Frequency 800 Hz
Table SVF110-2
FSVF110-1
2
Underfrequency Transients
Low Frequency 360 Hz
Table SVF110-2
FSVF110-2
3
Combined Transient
360 Hz to 800 Hz
Table SVF110-2
FSVF110-3
SVF201
Power Interrupt
400-1 115V RMS, 400 Hz nominal settings
0V for 50 msec
Table SVF201-2
FSVF201-400-1
360-1 115V RMS, 360 Hz nominal settings
0V for 50 msec
Table SVF201-2
FSVF201-360-1
600-1 115V RMS, 600 Hz nominal settings
0V for 50 msec
Table SVF201-2
FSVF201-600-1
800-1 115V RMS, 800 Hz nominal settings
0V for 50 msec
Table SVF201-2
FSVF201-800-1
SVF301
Abnormal Steady State Limits for Voltage and Frequency 100V to 125V RMS, 360Hz to 800 Hz Apply for 30 mins
FSVF301
SVF302
Abnormal Voltage Transients
400-1 400 Hz, Overvoltage Transients
Peak Voltage 180V RMS
Table SVF302-2 A-G
FSVF302-400-1
400-2 400 Hz, Undervoltage Transients
Low Voltage 45V RMS
Table SVF302-2 H-N
FSVF302-400-2
400-3 400 Hz, Combined Transient
45V RMS to 180V RMS
Table SVF302-2 O
FSVF302-400-3
360-1 360 Hz, Overvoltage Transients
Peak Voltage 180V RMS
Table SVF302-2 A-G
FSVF302-360-1
360-2 360 Hz, Undervoltage Transients
Low Voltage 45V RMS
Table SVF302-2 H-N
FSVF302-360-2
360-3 360 Hz, Combined Transient
45V RMS to 180V RMS
Table SVF302-2 O
FSVF302-360-3
600-1 600 Hz, Overvoltage Transients
Peak Voltage 180V RMS
Table SVF302-2 A-G
FSVF302-600-1
600-2 600 Hz, Undervoltage Transients
Low Voltage 45V RMS
Table SVF302-2 H-N
FSVF302-600-2
600-3 600 Hz, Combined Transient
45V RMS to 180V RMS
Table SVF302-2 O
FSVF302-600-3
800-1 800 Hz, Overvoltage Transients
Peak Voltage 180V RMS
Table SVF302-2 A-G
FSVF302-800-1
800-2 800 Hz, Undervoltage Transients
Low Voltage 45V RMS
Table SVF302-2 H-N
FSVF302-800-2
800-3 800 Hz, Combined Transient
45V RMS to 180V RMS
Table SVF302-2 O
FSVF302-800-3
SVF303
Abnormal Frequency Transients
Summary of Contents for 10001i
Page 2: ......
Page 3: ......
Page 6: ...ii This page intentionally left blank...
Page 38: ...User Manual 24 i Series iX Series Figure 3 5 Rear Panel View for the 3001i 3001iX...
Page 39: ...User Manual i Series iX Series 25 Figure 3 6 Rear Panel View for the 5001i 5001iX...
Page 43: ...User Manual i Series iX Series 29 Figure 3 8 Functional Test Setup...
Page 44: ...User Manual 30 i Series iX Series Figure 3 9 Single Phase 10000 VA System 10001iX i...
Page 46: ...User Manual 32 i Series iX Series Figure 3 11 Single Phase 15000 VA System 15001iX i...
Page 48: ...User Manual 34 i Series iX Series Figure 3 13 Connection With MODE Option...
Page 118: ...User Manual 104 i Series iX Series Figure 5 2 Power Source Module Block Diagram...
Page 121: ...User Manual i Series iX Series 107 Figure 5 3 5001i Internal Layout...
Page 122: ...User Manual 108 i Series iX Series Figure 5 4 Logic Board LED s...
Page 124: ...User Manual 110 i Series iX Series Figure 5 5 AC Power Stage Layout...
Page 125: ...User Manual i Series iX Series 111 Figure 5 6 AC Control Logic Block Diagram...
Page 138: ...User Manual 124 i Series iX Series Figure 6 3 Adjustment Location...
Page 152: ...User Manual 138 i Series iX Series Figure 9 4 Voltage Modulation...
Page 219: ...User Manual i Series iX Series 205 Figure 9 36 Example Connection With 5001iX and EOS 1...
Page 221: ...User Manual i Series iX Series 207 Figure 9 38 15003iX CTS EOS3 LR3...
Page 222: ...User Manual 208 i Series iX Series Figure 9 39 15003iX 3 EOS3...
Page 233: ...User Manual i Series iX Series 219 Figure 9 41 Example Connection With MODE iX...
Page 240: ...User Manual 226 i Series iX Series Figure 9 42 Example Connections With OMNI 1 18i...
Page 241: ...User Manual i Series iX Series 227 Figure 9 43 Example Connections With OMNI 3 18i...