9.1.2.5 Initial Setup
The
–160 option supports both AC and DC modes of operation. The correct mode is a function of
the EUT to be tested and the operator must select the corresponding operating mode first. This
can be done from the front panel if needed or using the CIGui32 program. Use of the CIGui32
program for all settings will be assumed for the remainder of this chapter.
The following twelve power groups are covered in the RTCA/DO-160 directive:
Category reference:
-
For ac equipment: A(CF), A(NF), and A(WF)
-
For dc equipment: A, B, Z
-
AC tests can be performed at 115V nominal or 230V nominal, except A(NF) and
A(CF) which can only be done at 115V nominal. All AC line voltage shown are L-N.
-
DC tests can be performed at 28V nominal or 14V nominal
Definitions:
A(CF):
designates ac equipment intended for use on aircraft electrical systems where the
primary power is from constant frequency (400 Hz) ac system.
A(NF):
designates ac equipment intended for use on aircraft electrical systems where the
primary power is from narrow variable frequency (360 to 650 Hz) ac system.
A(WF):
designates ac equipment intended for use on aircraft electrical systems where the
primary power is from wide variable frequency (360 to 800 Hz) ac system.
A:
designates dc equipment intended for use on aircraft electrical systems where the dc is
generated from primary power supplied from either a constant or variable frequency ac system.
B:
designates dc equipment intended for use on aircraft electrical systems supplied by engine-
driven alternator/rectifiers, or dc generators where a battery of significant capacity is floating on
the dc bus at all times.
Z:
designates dc equipment that may be used on all other types of aircraft electrical systems
applicable to these standards. Category Z shall be acceptable for use in lieu of Category A or
Category B.
The required steady state output settings for each power group must be selected based on the
type of EUT to be tested. These settings can be made from the front panel of the iX Series power
source or from the main CIGui32 control screen.
Summary of Contents for 10001i
Page 2: ......
Page 3: ......
Page 6: ...ii This page intentionally left blank...
Page 38: ...User Manual 24 i Series iX Series Figure 3 5 Rear Panel View for the 3001i 3001iX...
Page 39: ...User Manual i Series iX Series 25 Figure 3 6 Rear Panel View for the 5001i 5001iX...
Page 43: ...User Manual i Series iX Series 29 Figure 3 8 Functional Test Setup...
Page 44: ...User Manual 30 i Series iX Series Figure 3 9 Single Phase 10000 VA System 10001iX i...
Page 46: ...User Manual 32 i Series iX Series Figure 3 11 Single Phase 15000 VA System 15001iX i...
Page 48: ...User Manual 34 i Series iX Series Figure 3 13 Connection With MODE Option...
Page 118: ...User Manual 104 i Series iX Series Figure 5 2 Power Source Module Block Diagram...
Page 121: ...User Manual i Series iX Series 107 Figure 5 3 5001i Internal Layout...
Page 122: ...User Manual 108 i Series iX Series Figure 5 4 Logic Board LED s...
Page 124: ...User Manual 110 i Series iX Series Figure 5 5 AC Power Stage Layout...
Page 125: ...User Manual i Series iX Series 111 Figure 5 6 AC Control Logic Block Diagram...
Page 138: ...User Manual 124 i Series iX Series Figure 6 3 Adjustment Location...
Page 152: ...User Manual 138 i Series iX Series Figure 9 4 Voltage Modulation...
Page 219: ...User Manual i Series iX Series 205 Figure 9 36 Example Connection With 5001iX and EOS 1...
Page 221: ...User Manual i Series iX Series 207 Figure 9 38 15003iX CTS EOS3 LR3...
Page 222: ...User Manual 208 i Series iX Series Figure 9 39 15003iX 3 EOS3...
Page 233: ...User Manual i Series iX Series 219 Figure 9 41 Example Connection With MODE iX...
Page 240: ...User Manual 226 i Series iX Series Figure 9 42 Example Connections With OMNI 1 18i...
Page 241: ...User Manual i Series iX Series 227 Figure 9 43 Example Connections With OMNI 3 18i...