User Manual
136
i Series / iX Series
9.1.1.5 AC TESTS
Note: Prior to test selection the standard and the group selection are required. Use the shuttle to
select the standard and the group if applicable.
9.1.1.5.1 Normal state test
Scroll to the NORMAL STATE AC entry using the up and down cursor keys. Press the ENTER
key to select the NORMAL STATE screens. The screen will appear as shown in Figure 9-3.
Figure 9-3: Normal state
The DO160 NORMAL 1 and NORMAL 2 screens have the following tests:
1
VOLT FREQ MIN
2
VOLT FREQ MAX
3
VOLT UNBALANCE
4
WAVEFORM DISTORTION
5
VOLT MODULATION
6
FREQ MODULATION
7
POWER INTERRUPT
8
VOLTAGE SURGE
9
FREQ TRANSIENT (group 1)
FREQ VARIATION (group 2 & 3)
The above tests can be selected by scrolling to the highlighted selection using the up and down
key and the ENTER key to start the selected test. For some of these tests, numeric data entry
may be required to define the test number or the modulation rate.
VOLT FREQ MIN
Standard/Group
RTCA
Group1
Group2
Group3
Voltage
1
100
104
104
104
3
101.5
105.5
105.5
105.5
Frequency
380
390
360
360
Table 9-1: Normal Voltage and Frequency minimum
Standard/Group
RTCA
Group1
Group2
Group3
Voltage
1
122
122
122
122
3
120.5
120.5
120.5
120.5
Frequency
420
410
650
800
Table 9-2: Normal Voltage and Frequency Maximum
This test will set the voltage and frequency to levels defined by Table 9-1. The test will last for 30
minutes. The test will be repeated for the Group 2 and 3 using the Voltage setting from Table 9-2
and the frequency from Table 9-1. The
key (backspace) will terminate the test at any time.
Summary of Contents for 10001i
Page 2: ......
Page 3: ......
Page 6: ...ii This page intentionally left blank...
Page 38: ...User Manual 24 i Series iX Series Figure 3 5 Rear Panel View for the 3001i 3001iX...
Page 39: ...User Manual i Series iX Series 25 Figure 3 6 Rear Panel View for the 5001i 5001iX...
Page 43: ...User Manual i Series iX Series 29 Figure 3 8 Functional Test Setup...
Page 44: ...User Manual 30 i Series iX Series Figure 3 9 Single Phase 10000 VA System 10001iX i...
Page 46: ...User Manual 32 i Series iX Series Figure 3 11 Single Phase 15000 VA System 15001iX i...
Page 48: ...User Manual 34 i Series iX Series Figure 3 13 Connection With MODE Option...
Page 118: ...User Manual 104 i Series iX Series Figure 5 2 Power Source Module Block Diagram...
Page 121: ...User Manual i Series iX Series 107 Figure 5 3 5001i Internal Layout...
Page 122: ...User Manual 108 i Series iX Series Figure 5 4 Logic Board LED s...
Page 124: ...User Manual 110 i Series iX Series Figure 5 5 AC Power Stage Layout...
Page 125: ...User Manual i Series iX Series 111 Figure 5 6 AC Control Logic Block Diagram...
Page 138: ...User Manual 124 i Series iX Series Figure 6 3 Adjustment Location...
Page 152: ...User Manual 138 i Series iX Series Figure 9 4 Voltage Modulation...
Page 219: ...User Manual i Series iX Series 205 Figure 9 36 Example Connection With 5001iX and EOS 1...
Page 221: ...User Manual i Series iX Series 207 Figure 9 38 15003iX CTS EOS3 LR3...
Page 222: ...User Manual 208 i Series iX Series Figure 9 39 15003iX 3 EOS3...
Page 233: ...User Manual i Series iX Series 219 Figure 9 41 Example Connection With MODE iX...
Page 240: ...User Manual 226 i Series iX Series Figure 9 42 Example Connections With OMNI 1 18i...
Page 241: ...User Manual i Series iX Series 227 Figure 9 43 Example Connections With OMNI 3 18i...