configuration apply
Configuration File Manager Commands
page 44-2
OmniSwitch CLI Reference Guide
March 2011
configuration apply
Applies a configuration file to the switch. Files may be applied immediately or after a designated timer
session. With the timer session option, files are applied either at a scheduled date and time or after a
specified period of time (i.e., a countdown) has passed.
configuration apply filename [at hh:mm month dd [year]] | [in hh[:mm]] [verbose]
Syntax Definitions
filename
The name of the configuration text file to be applied to the switch
(e.g.,
newfile1
)
.
in
hh[:mm]
Designates a timer session in which the configuration file is applied
after a specific amount of time (i.e., a countdown) has passed. Values
for
hh
range from 00 through 23. Values for
mm
range from 00 through
59.
verbose
When verbose is entered, information is displayed on your workstation’s
console as each command in the configuration file is applied.
Defaults
By default,
verbose
error checking is not performed.
Platforms Supported
OmniSwitch 10K
Usage Guidelines
•
The
configuration apply
command only applies settings to the running configuration. The
boot.cfg
file does not get overwritten.
•
It is recommended that you check all configuration files for syntax errors before applying them to your
switch.
•
To schedule a timer session in which a file is applied at a specific date and time, enter
at
followed by
the hour, minute, month, day, and year. The switch assumes either the current calendar year or the next
calendar year for dates beginning January 1.
•
To schedule a timer session in which a file is applied after a specific amount of time (i.e., a countdown)
has passed, enter
in
followed by the number of hours and minutes.
•
Verbose mode is not supported for timer sessions.
at
hh:mm
{dd month | month dd} [year]
Designates a timer session in which a configuration file is applied at a
specified date and time in the future. Values for
hh
range from 00
through 23. Values for
mm
range from 00 through 59. Values for
dd
range from 01 through 31. Values for month range from january through
december. The switch assumes either the current year or the next calen-
dar year for month and day pairs that precede the current date.
Summary of Contents for 060321-10, Rev. B
Page 1: ...Part No 060321 10 Rev B March 2011 OmniSwitch CLI Reference Guide www alcatel lucent com...
Page 36: ...Technical Support About This Guide page xxxvi OmniSwitch CLI Reference Guide March 2011...
Page 108: ...show udld status port UDLD Commands page 2 22 OmniSwitch CLI Reference Guide March 2011...
Page 142: ...show vlan members VLAN Management Commands page 4 16 OmniSwitch CLI Reference Guide March 2011...
Page 922: ...show ip ospf restart OSPF Commands page 17 88 OmniSwitch CLI Reference Guide March 2011...
Page 968: ...show ipv6 ospf interface OSPFv3 Commands page 18 46 OmniSwitch CLI Reference Guide March 2011...
Page 1414: ...show ip dvmrp tunnel DVMRP Commands page 22 34 OmniSwitch CLI Reference Guide March 2011...
Page 1540: ...show ipv6 pim sgroute PIM Commands page 23 126 OmniSwitch CLI Reference Guide March 2011...
Page 1888: ...show aaa priv hexa AAA Commands page 28 58 OmniSwitch CLI Reference Guide March 2011...
Page 1902: ...show port mapping Port Mapping Commands page 29 14 OmniSwitch CLI Reference Guide March 2011...
Page 1960: ...show sflow poller sFlow Commands page 32 18 OmniSwitch CLI Reference Guide March 2011...
Page 2226: ...ftp File Management Commands page 42 38 OmniSwitch CLI Reference Guide March 2011...
Page 2284: ...show snmp trap config SNMP Commands page 45 32 OmniSwitch CLI Reference Guide March 2011...
Page 2294: ...show dns DNS Commands page 46 10 OmniSwitch CLI Reference Guide March 2011...
Page 2350: ...OmniSwitch CLI Reference Guide March 2011 page 22 DNS Commands...