spantree auto-vlan-containment
Distributed Spanning Tree Commands
page 5-32
OmniSwitch CLI Reference Guide
March 2011
spantree auto-vlan-containment
Enables or disables Auto VLAN Containment (AVC). When enabled, AVC prevents a port that has no
VLANs mapped to an Multiple Spanning Tree Instance (MSTI) from becoming the root port for that
instance. Such ports are automatically assigned an infinite path cost value to make them an inferior choice
for root port.
spantree [msti msti_id] auto-vlan-containment {enable | disable}
Syntax Definitions
msti_id
An existing MSTI ID number. A range of VLANs are
associated to an MSTI ID number.
enable
Enables automatic VLAN containment.
disable
Disables automatic VLAN containment.
Defaults
By default, automatic VLAN containment is disabled.
Platforms Supported
OmniSwitch 10K
Usage Guidelines
•
The AVC feature is not active for any MSTI until it is globally enabled. To globally enable this feature,
use the
spantree auto-vlan-containment
command but do not specify an
msti_ id
.
•
When AVC is globally enabled, it is active for all MSTIs. To disable AVC for a single instance,
specify the
msti_id
for the instance and use the
disable
form of this command.
•
Use the
enable
form of this command and specify an
msti_id
to enable AVC for an instance that was
previously disabled.
•
An administratively set port path cost takes precedence and prevents AVC configuration of the path
cost. However, if the port path cost is administratively set to zero, then the path cost is reset to the
default value.
•
Note that when AVC is disabled, a port assigned to a VLAN that is not mapped to a specific instance,
can become the root port for that instance and cause a loss of connectivity between other VLANs.
•
AVC does not have any effect on root bridges.
Examples
-> spantree auto-vlan-containment enable
-> spantree auto-vlan-containment disable
-> spantree msti 1 auto-vlan-containment disable
-> spantree msti 1 auto-vlan-containment enable
Summary of Contents for 060321-10, Rev. B
Page 1: ...Part No 060321 10 Rev B March 2011 OmniSwitch CLI Reference Guide www alcatel lucent com...
Page 36: ...Technical Support About This Guide page xxxvi OmniSwitch CLI Reference Guide March 2011...
Page 108: ...show udld status port UDLD Commands page 2 22 OmniSwitch CLI Reference Guide March 2011...
Page 142: ...show vlan members VLAN Management Commands page 4 16 OmniSwitch CLI Reference Guide March 2011...
Page 922: ...show ip ospf restart OSPF Commands page 17 88 OmniSwitch CLI Reference Guide March 2011...
Page 968: ...show ipv6 ospf interface OSPFv3 Commands page 18 46 OmniSwitch CLI Reference Guide March 2011...
Page 1414: ...show ip dvmrp tunnel DVMRP Commands page 22 34 OmniSwitch CLI Reference Guide March 2011...
Page 1540: ...show ipv6 pim sgroute PIM Commands page 23 126 OmniSwitch CLI Reference Guide March 2011...
Page 1888: ...show aaa priv hexa AAA Commands page 28 58 OmniSwitch CLI Reference Guide March 2011...
Page 1902: ...show port mapping Port Mapping Commands page 29 14 OmniSwitch CLI Reference Guide March 2011...
Page 1960: ...show sflow poller sFlow Commands page 32 18 OmniSwitch CLI Reference Guide March 2011...
Page 2226: ...ftp File Management Commands page 42 38 OmniSwitch CLI Reference Guide March 2011...
Page 2284: ...show snmp trap config SNMP Commands page 45 32 OmniSwitch CLI Reference Guide March 2011...
Page 2294: ...show dns DNS Commands page 46 10 OmniSwitch CLI Reference Guide March 2011...
Page 2350: ...OmniSwitch CLI Reference Guide March 2011 page 22 DNS Commands...