Distributed Spanning Tree Commands
spantree cist admin-edge
OmniSwitch CLI Reference Guide
March 2011
page 5-55
spantree cist admin-edge
Configures the administrative edge port status for a port or a link aggregate of ports for the flat mode
Common and Internal Spanning Tree (CIST).
spantree cist {port slot/port[-port2] | linkagg linkagg_id[-linkagg_id2]} admin-edge {enable | disable}
Syntax Definitions
slot/port[-port2]
The slot number and port number of the physical port. Use a hyphen to
specify a range of ports (4/1-8)
.
linkagg_id[-linkagg_id2]
The link aggregate ID number. Use a hyphen to specify a range of IDs
enable
Enables the administrative edge port status for the specified port-CIST
instance.
disable
Disables the administrative edge port status for the specified port-CIST
instance.
Defaults
By default, the administrative edge port status is disabled (off).
Platforms Supported
OmniSwitch 10K
Usage Guidelines
•
This command only applies to the port connection type for the CIST instance regardless of which oper-
ating mode (flat or per-VLAN) is active on the switch.
•
If the switch is running in the per-VLAN mode when this command is used, the specified edge port
status is not active for the CIST instance until the switch is configured to run in the flat Spanning Tree
mode.
•
The administrative edge port status is used to determine if a port is an edge or non-edge port when
automatic edge port configuration (
auto-edge
) is disabled for the port. However, if
auto-edge
is
enabled for the port, then the administrative status is overridden.
•
Rapid transition of a designated port to forwarding can only occur if the port connection type is defined
as a point to point or an edge port. Rapid transition of an alternate port role to a root port role is not
affected by the port connection type definition.
•
Configure ports that connect to a host (PC, workstation, server, and so on) as edge ports to avoid
unnecessary topology changes when these ports go active. This also prevents the flushing of learned
MAC addresses on these ports if a topology change occurs as a result of another non-edge port going
active. If an edge port receives a BPDU, it operationally reverts back to a no point-to-point connection
type.
Summary of Contents for 060321-10, Rev. B
Page 1: ...Part No 060321 10 Rev B March 2011 OmniSwitch CLI Reference Guide www alcatel lucent com...
Page 36: ...Technical Support About This Guide page xxxvi OmniSwitch CLI Reference Guide March 2011...
Page 108: ...show udld status port UDLD Commands page 2 22 OmniSwitch CLI Reference Guide March 2011...
Page 142: ...show vlan members VLAN Management Commands page 4 16 OmniSwitch CLI Reference Guide March 2011...
Page 922: ...show ip ospf restart OSPF Commands page 17 88 OmniSwitch CLI Reference Guide March 2011...
Page 968: ...show ipv6 ospf interface OSPFv3 Commands page 18 46 OmniSwitch CLI Reference Guide March 2011...
Page 1414: ...show ip dvmrp tunnel DVMRP Commands page 22 34 OmniSwitch CLI Reference Guide March 2011...
Page 1540: ...show ipv6 pim sgroute PIM Commands page 23 126 OmniSwitch CLI Reference Guide March 2011...
Page 1888: ...show aaa priv hexa AAA Commands page 28 58 OmniSwitch CLI Reference Guide March 2011...
Page 1902: ...show port mapping Port Mapping Commands page 29 14 OmniSwitch CLI Reference Guide March 2011...
Page 1960: ...show sflow poller sFlow Commands page 32 18 OmniSwitch CLI Reference Guide March 2011...
Page 2226: ...ftp File Management Commands page 42 38 OmniSwitch CLI Reference Guide March 2011...
Page 2284: ...show snmp trap config SNMP Commands page 45 32 OmniSwitch CLI Reference Guide March 2011...
Page 2294: ...show dns DNS Commands page 46 10 OmniSwitch CLI Reference Guide March 2011...
Page 2350: ...OmniSwitch CLI Reference Guide March 2011 page 22 DNS Commands...