Section 7: SCPI command reference
Model 2281S-20-6 DC Power Supply and Battery Simulator Reference Manual
7-172
077114601 / March 2019
Example
:SYST:PASS:LOCK "admin"
Disable the current interface
Also see
(on page 7-172)
(on page 7-173)
(on page 7-174)
:SYSTem:PASSword:MODE
This command sets the protection mode for the remote connection.
Type
Affected by
Where saved
Default value
Command only
Power cycle
Instrument reset
Recall settings
Save settings
NONE
Usage
:SYSTem:PASSword:MODE <value>
<value>
Enable the password protection:
ALL
Disable the password protection:
NONE
Details
When the password protection is set to
ALL
, you must enter a password when sending the following
commands:
:SYSTem:PASSword:LOCK
:SYSTem:PASSword:UNLock
Example
:SYST:PASS:MODE ALL
Enable the password protection.
Also see
(on page 7-173)
(on page 7-174)