Model 2281S-20-6 DC Power Supply and Battery Simulator Reference Manual
Section 5: Application examples
077114601 / March 2019
5-15
To test a battery and generate a battery model using SCPI commands:
Connect the battery to the instrument.
Send the commands:
:BATT:TEST:VOLT V1
:BATT:OUTP ON
Set the discharging target voltage to V1.
Set the end current to A1.
Turn
OUTPUT
on in the front panel to discharge the battery.
Send the commands:
:BATT:TEST:SENS:AH:VFUL V2
:BATT:TEST:SENS:AH:ILIM A2
:BATT:TEST:SENS:AH:ESRI S30
Set the V-Full to V2.
Set the maximum charging limit to A2.
Set the end current to 1 mA.
Set the sampling interval to 30 s.
Send the commands:
:BATT:TEST:SENS:AH:EXEC STAR
:STAT:OPER:INST:ISUM:COND?
:BATT:TEST:SENS:AH:GMOD:RANG 2.5, 3.7
:BATT:TEST:SENS:AH:GMOD:SAVE:INTE 1
Start the measurement.
Query whether the measurement is done.
Set the range for generating battery model if needed
Save the battery model to the internal memory.
The values V1, V2, A1, and A2 are to be provided by the battery manufacturer. Improper settings
might damage the battery.