Model 2281S-20-6 DC Power Supply and Battery Simulator Reference Manual
Section 7: SCPI command reference
077114601 / March 2019
7-113
:OUTPut[:STATe]
This command enables or disables the source output.
Type
Affected by
Where saved
Default value
Command and query
Recall settings
Instrument reset
Power cycle
Save settings
0 (OFF)
Usage
:OUTPut[:STATe] <state>
:OUTPut[:STATe] <state>,<channel>
:OUTPut[:STATe]?
<state>
Turn source off:
OFF
or
0
Turn source on:
ON
or
1
Disable source:
DISable
or
2
<channel>
The channel number (default value is CH1):
Channel 1: CH1
Channel 2: CH2
Details
Measurements cannot be made while the source is off.
Example
:OUTP ON
Switch the source output of the instrument to ON.
Also see
None