Model 2281S-20-6 DC Power Supply and Battery Simulator Reference Manual
Section 3: Functions and features
077114601 / March 2019
3-5
Figure 70: Graph auto adjustment
To set the manual adjustment on the front panel:
1. Press the
MENU
key.
2. Under Views, select
Graph
.
3. Select the button next to
I Manual Adjust
or
V Manual Adjust
and press
ENTER
.
4. Press the
Scale
soft key. The scale screen is displayed.
5. Enter a value for scale. There are seven divisions on the Y-axis. The minimum value for the
current scale is 10 µA. The minimum value for the voltage scale is 100 µV.
6. Press the
Offset
soft key. The offset screen is displayed.
7. Enter a value for offset. For parameters, refer to the following table.
Model number
Current offset
Voltage offset
2281S
–1 A to 6.1 A
–20 V to 20 V
Before configuring the scale or offset, make sure the auto adjustment is disabled. Otherwise, you
cannot change these settings.