275
Memory Operation
Section 10-2
10-2-2 Repeat Operation
Overview
• Any operation can be executed repeatedly under memory operation using
the bank end completion code.
• When the completion code of any positioning sequence is set to bank
end, positioning is stopped after the operation for that sequence has been
completed.
• When operation is started again, it returns to the sequence number that
was previously enabled and executes the positioning.
Operation Example
The following is an example of repeating a particular operation.
1,2,3...
1.
When the operation start switch is turned ON at the origin, the program
outputs 1,000 pulses CW on the X axis and stops. (Independent)
(First, set the origin to “0” either by performing an origin search or by exe-
cuting PRESENT POSITION PRESET.)
2.
When the operation start switch turns ON, positioning is executed using
the continuous completion code, and the program positions to 4,500 puls-
es CW on the X axis and stops.
3.
When the operation start switch turns ON, positioning is executed using
the continuous completion code. The program positions to the X axis origin
and stops.
4.
When the operation start switch turns ON, the operations in steps 1 to 3
above are repeated.
Setting the PCU
Unit number:
Unit #0
PCU used:
NC113
Operation
starts
Operation
starts
Operation
starts
Speed (pps)
X axis
Содержание CJ1W-C113 - REV 02-2008
Страница 1: ...Position Control Units Cat No W397 E1 07 SYSMAC CJ1W NC113 213 413 133 233 433 OPERATION MANUAL ...
Страница 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Страница 3: ...iv ...
Страница 13: ...xiv ...
Страница 15: ...xvi ...
Страница 19: ...xx ...
Страница 27: ...xxviii Conformance to EC Directives 6 ...
Страница 43: ...16 Control System Principles Section 1 7 ...
Страница 47: ...20 Basic Procedures Section 2 ...
Страница 139: ...112 Examples of Parameter Settings Section 4 9 ...
Страница 173: ...146 Transferring Data with CX Position Section 5 7 ...
Страница 223: ...196 Sample Program Section 7 7 ...
Страница 259: ...232 Sample Program Section 8 10 ...
Страница 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Страница 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Страница 385: ...358 Common Parameter Area Appendix C ...
Страница 399: ...372 Parameter Coding Sheets Appendix E ...