222
Transferring Positioning Sequences
Section 8-7
8-7-2
Transferring 100 Positioning Sequences from CPU Unit to PCU
This example is based on the following conditions:
• The PCU used is a NC413 with the unit number set to 0.
• The beginning word of the operating data area is set to D00500.
• The data for sequence numbers 0 to 99 is set in EM bank 0 from word 0.
Ladder Program
The work bit R1 is used to start write.
DIFU R1
MOV
012C
D00500
200814
MOV
#000E
D00501
MOV
#0000
D00502
R1
Write switch
Work bit
Data Transferring
Flag
MOV
#1000
D00503
200112
Sets the total number of
write words. In this case,
sets to 12C (Hex).
(100 positioning sequences
×
3 words = 300 words)
Sets the area in the CPU Unit
used to set the positioning
sequences (EM Area, bank 0).
Set the beginning word of the
area in the DM or EM Area used
to set the positioning sequences.
In this case, sets to 0000.
Sets the beginning address of the
area in the PCU to which the
positioning sequences are to be
written. In this case, sets to 1000.
WRITE DATA
Operating data area
D00500
D00501
D00502
D00503
012C
000E
0000
1000
Write source area
Number of write words
Write destination address
Write source word
Positioning sequences (set in EM Area, bank 0)
E00000
E00001
E00002
:
E00297
E00298
E00299
Sequence #0
(3 words)
Sequence #99
(3 words)
:
200112
Содержание CJ1W-C113 - REV 02-2008
Страница 1: ...Position Control Units Cat No W397 E1 07 SYSMAC CJ1W NC113 213 413 133 233 433 OPERATION MANUAL ...
Страница 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Страница 3: ...iv ...
Страница 13: ...xiv ...
Страница 15: ...xvi ...
Страница 19: ...xx ...
Страница 27: ...xxviii Conformance to EC Directives 6 ...
Страница 43: ...16 Control System Principles Section 1 7 ...
Страница 47: ...20 Basic Procedures Section 2 ...
Страница 139: ...112 Examples of Parameter Settings Section 4 9 ...
Страница 173: ...146 Transferring Data with CX Position Section 5 7 ...
Страница 223: ...196 Sample Program Section 7 7 ...
Страница 259: ...232 Sample Program Section 8 10 ...
Страница 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Страница 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Страница 385: ...358 Common Parameter Area Appendix C ...
Страница 399: ...372 Parameter Coding Sheets Appendix E ...