325
Error Code Lists
Section 11-5
11-5-2 Command Execution Check
Data Checks for Data-writing Commands
Item
Name
Code
Cause
Clearing
method
Operation after
error
Initial speed
Initial speed
error
1000
The axis parameters’ initial speed set-
ting exceeds the maximum speed des-
ignation.
Transfer the data
again after
checking and
correcting it.
When this error
occurs during
data transfer, all
data (including
the data with the
error) specified
for transfer will
be lost.
All operating
axes will be
decelerated to a
stop.
Initial pulse des-
ignation error
1001
The initial pulse designation is not set to
0000 or 0001.
Maximum
speed
Maximum speed
error
1010
The axis parameters’ maximum speed
setting is outside the settable range (1
to 500 kpps).
Acceleration/
Deceleration
data
Acceleration
time error
1310
The axis parameters’ origin search
acceleration time setting is outside the
settable range (0 to 250 s).
Acceleration
time error
1311
to
1319
An acceleration time setting (1 to 9) is
outside the settable range (0 to 250 s).
(The rightmost digit of the error code
indicates the setting with the error.)
Deceleration
time error
1320
The axis parameters’ origin search
deceleration time setting is outside the
settable range (0 to 250 s).
Deceleration
time error
1321
to
1329
A deceleration time setting (1 to 9) is
outside the settable range (0 to 250 s).
(The rightmost digit of the error code
indicates the setting with the error.)
Acceleration/
Deceleration
curve error
1330
The axis parameters’ acceleration/
deceleration curve setting is not 0 or 1.
Positioning mon-
itor time error
1332
The axis parameters’ positioning moni-
tor time is outside the settable range (0
to 9,999 ms).
Speed data
Speed error
1500
to
1599
A speed setting is outside the settable
range (1 pps to 1,000 kpps).
(The last two digits of the code indicate
the speed data number where the error
occurred.)
Origin search
Origin compen-
sation error
1600
The axis parameters’ origin compensa-
tion setting is outside the settable range
(–1,073,741,823 to 1,073,741,823).
Origin search
high speed error
1601
The axis parameters’ origin search high
speed setting exceeds the axis parame-
ters’ maximum speed setting.
Origin search
proximity speed
error
1602
The axis parameters’ proximity speed
setting exceeds the axis parameters’
maximum speed setting.
Origin search
speed inconsis-
tent
1603
The axis parameters’ origin search high
speed setting is less than or equal to
the origin search proximity speed set-
ting.
Operation mode
selection error
1604
The axis parameters’ origin search
operating mode selection setting is not
0, 1, 2, or 3.
Origin search
operation error
1605
The axis parameters’ origin search
operation setting is not 0, 1, or 2.
Origin search
direction error
1606
The axis parameters’ origin search
direction designation is not 0 or 1.
Содержание CJ1W-C113 - REV 02-2008
Страница 1: ...Position Control Units Cat No W397 E1 07 SYSMAC CJ1W NC113 213 413 133 233 433 OPERATION MANUAL ...
Страница 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Страница 3: ...iv ...
Страница 13: ...xiv ...
Страница 15: ...xvi ...
Страница 19: ...xx ...
Страница 27: ...xxviii Conformance to EC Directives 6 ...
Страница 43: ...16 Control System Principles Section 1 7 ...
Страница 47: ...20 Basic Procedures Section 2 ...
Страница 139: ...112 Examples of Parameter Settings Section 4 9 ...
Страница 173: ...146 Transferring Data with CX Position Section 5 7 ...
Страница 223: ...196 Sample Program Section 7 7 ...
Страница 259: ...232 Sample Program Section 8 10 ...
Страница 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Страница 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Страница 385: ...358 Common Parameter Area Appendix C ...
Страница 399: ...372 Parameter Coding Sheets Appendix E ...