99
Operating Data Area
Section 4-6
User-specified DM/EM Area Words
If 000D (user-specified DM Area words) or 0X0E, where X = 0 to 9, A, B, or C
(user-specified EM Area words) is set for the common parameter used for the
operating data area designation (word m), the beginning word, l, of the operat-
ing data area will be determined by the setting of word m+1, which specifies
the beginning word of operating data area.
The operating data area is divided into an area for data that is output from the
CPU Unit to the PCU and an area for data that is input from the PCU to the
CPU Unit. The memory allocation of the operating data area is shown in the
following tables. For more details, refer to the section on the relevant function.
Operating Data Area
Common to All Axes
Example 1:
Example 2:
m
0 0 0 D
m+1
1 F 4 0
(1F40 Hex=8000)
I=D8000
m
0 2 0 E
m+2
3 A 9 8
(3A98 Hex=15000)
I=E2_15000
I/O
Words
Name
Operation
Reference
Output (CPU
Unit to PCU)
I
Operating data for
data transfer
Number of
write words
Specifies the number of words written
from the CPU Unit to the PCU.
SECTION 5
Transferring
and Saving
Data
I+1
Write source
area
Specifies the area containing the data
to be written from the CPU Unit to the
PCU.
I+2
Write source
word
Specifies the beginning word of the
data to be written from the CPU Unit to
the PCU.
I+3
Write
destination
address
Specifies the address in the PCU to
which the data is to be written.
I+4
Number of
read words
Specifies the number of words to be
read from the PCU to the CPU Unit.
I+5
Read source
address
Specifies the address in the PCU from
which the data is to be read.
l+6
Read
destination
area
Specifies the area used to output the
data read from the PCU.
l+7
Read
destination
word
Specifies the word used to output the
data read from the PCU.
Содержание CJ1W-C113 - REV 02-2008
Страница 1: ...Position Control Units Cat No W397 E1 07 SYSMAC CJ1W NC113 213 413 133 233 433 OPERATION MANUAL ...
Страница 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Страница 3: ...iv ...
Страница 13: ...xiv ...
Страница 15: ...xvi ...
Страница 19: ...xx ...
Страница 27: ...xxviii Conformance to EC Directives 6 ...
Страница 43: ...16 Control System Principles Section 1 7 ...
Страница 47: ...20 Basic Procedures Section 2 ...
Страница 139: ...112 Examples of Parameter Settings Section 4 9 ...
Страница 173: ...146 Transferring Data with CX Position Section 5 7 ...
Страница 223: ...196 Sample Program Section 7 7 ...
Страница 259: ...232 Sample Program Section 8 10 ...
Страница 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Страница 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Страница 385: ...358 Common Parameter Area Appendix C ...
Страница 399: ...372 Parameter Coding Sheets Appendix E ...