297
Two-axis Linear Interpolation
Section 10-4
Program
W030 is used as a work word.
Operation start switch
Takes the rising edge of
the operation start
switch.
Busy Flag
Sets #0 for the
sequence number.
Sequence
Number Enable
Enables the
sequence number.
Start
No Origin
Flag
Only executed
when starting
the first time.
Executed
when starting
from the
second time
onwards.
W03000
200413
200406
W03001
DIFU
W03000
D00516
200000
W03014
W03015
W03001
W03001
W03000
W03001
W03014
W03015
200001
200001