129
Reading Data with the READ DATA Bit
Section 5-3
Operating Data Area
5-3-3
Timing Chart for Reading Data
Reading data is possible even during axis operation.
It is not possible to write and read data at the same time.
The following diagram is a timing chart for reading data from a 4-axis PCU.
After the data reading operation has been completed, the Data Transferring
Flag (word n+8, bit 14) is turned from ON to OFF. If an error occurs during
data transfer, the Error Flag (word n+8, bit 12) will be turned ON and the error
code will be output to n+10 in the operating memory area. Check this error
code to determine the cause of the error and correct it.
Name
Model
Operati
ng data
area
Bit
Contents
Number of
read words
Same
for all
models
I+4
00 to
15
Read
source
address
I+5
00 to
15
Read desti-
nation area
I+6
00 to
15
Read desti-
nation word
I+7
00 to
15
15
00
Specifies the number of words to be read to the
CPU Unit. Setting range: 0001 to 0304 Hex (1 to
772 words)
15
00
Specifies the beginning address of the area in the
PCU from which parameters and data are read.
For details of the PCU's internal addresses,
refer to
SECTION 4 Data Areas
.
EM bank
designation
DM/EM
designation
15
08 07
00
Specifies the area where the parameters and data
read from the PCU are stored.
DM/EM designation:
0D: Designates DM Area
0E: Designates
EM Area EM bank designation:
Specifies the EM Area bank number if the EM
Area is designated in bits 00 to 07.Setting
range: 00 to 0C (banks 0 to C)
15
00
Specifies the beginning word of the area in the CPU
Unit's DM or EM Area in which parameters and data
are stored.
Setting range: 0000 to 7FFF Hex (Words 0 to 32767)
Number of read words (l+4)
Read source address (l+5)
Read destination area (l+6)
Read destination word (l+7)
READ DATA (n+1, 13)
Data Transferring Flag
(n+8, 14)
(9 words)
64 Hex (100)
Содержание CJ1W-C113 - REV 02-2008
Страница 1: ...Position Control Units Cat No W397 E1 07 SYSMAC CJ1W NC113 213 413 133 233 433 OPERATION MANUAL ...
Страница 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Страница 3: ...iv ...
Страница 13: ...xiv ...
Страница 15: ...xvi ...
Страница 19: ...xx ...
Страница 27: ...xxviii Conformance to EC Directives 6 ...
Страница 43: ...16 Control System Principles Section 1 7 ...
Страница 47: ...20 Basic Procedures Section 2 ...
Страница 139: ...112 Examples of Parameter Settings Section 4 9 ...
Страница 173: ...146 Transferring Data with CX Position Section 5 7 ...
Страница 223: ...196 Sample Program Section 7 7 ...
Страница 259: ...232 Sample Program Section 8 10 ...
Страница 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Страница 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Страница 385: ...358 Common Parameter Area Appendix C ...
Страница 399: ...372 Parameter Coding Sheets Appendix E ...