10
- 66
10.4 Checking the Error Description with the CC IE Control Network Diagnostics
10.4.12 CPU module power stop error
10
TROUBLESHOOTING
10.4.12
CPU module power stop error
The following explains the procedures to be taken when power of the CPU module, to
which the CC-Link IE controller network module with the external power supply function is
installed, has been down.
The CC IE Control Network Diagnostics is not executable for the faulty station because its
CPU module has been powered OFF.
(1) When GX Developer connected station is normally operating
Figure 10.53 When GX Developer connected station is normally operating
Select the own station.
An error has occurred on station No.4.
Select station No.4.
Click the [Error details] button.
The Error factor indicates that the CPU module has been powered OFF.
Take corrective actions according to the troubleshooting.
External power supply
External power supply
Control station
No.1
Normal station
No.2
Normal
station
No.4
Normal station
No.3
Selected
station
Control
station
No.1
Normal station
No.2
Normal
station
No.4
Normal station
No.3
Selected
station