
APPENDICES
Appendix 2 Link Special Register (SW) List
App
- 27
9
DE
DICA
T
E
D
INS
T
RUCT
IONS
10
T
R
OUB
L
E
S
HO
OT
IN
G
APPENDI
CES
INDEX
SW00A0 to
SW00A7
Baton pass status of
each station
Stores the baton pass status of each station.
0: Baton pass normally operating station
1: Baton pass faulty station
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error is held.
• The reserved station and the station No. later than the largest one are
excepted.
SW00B0 to
SW00B7
Cyclic transmission
status of each station
Stores the cyclic transmission status of each station.
0: Cyclic transmission normally operating station
1: Cyclic transmission faulty station
If a CPU module installed together with the CC-Link IE controller network
module with external power supply function is turned OFF, detection of a data
link error may take more time than usual.
For immediate detection of a data link error, program an interlock using the
link relay (LB) in each station's send range.
(
Section 8.1.3 Program example of cyclic transmission)
When group cyclic transmission is used, a station whose shared group is
different from the group of the own station is detected as a cyclic
transmission error station. (Including reserved stations)
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error is held.
• The station No. later than the largest one are excepted.
Table App.4 Link special register (SW) list (Continued)
No.
Name
Description
Availability
Control
station
Normal
station
SW00A1
SW00A2
SW00A3
SW00A4
SW00A5
SW00A6
SW00A7
SW00A0 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
-
-
-
-
-
-
-
-
120 119 118 117 116 115 114 113
Each number in the table represents station No.
SW00B1
SW00B2
SW00B3
SW00B4
SW00B5
SW00B6
SW00B7
SW00B0 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
-
-
-
-
-
-
-
-
120 119 118 117 116 115 114 113
Each number in the table represents station No.
Link special register (SW): SW00A0 to SW00B7
Содержание QJ71GP21-SX
Страница 1: ......
Страница 2: ......
Страница 644: ...App 94 Appendix 6 External Dimensions Appendix 6 2 QJ71GP21S SX APPENDICES Memo ...
Страница 649: ......
Страница 650: ......