SW0090
Loopback information
SW0065
Loopback information
(Content
changed)
• The CC-Link IE controller
network module does not
store the forward or reverse
loop error.
• Although the CC-Link IE
controller network uses
two-core cables, loopback is
performed even if a
disconnection or error is
detected on one side.
SW0091 to
SW0094
Forward loop status of each
station
SW0070
IN-side loopback station No.
(Content
changed)
Although the CC-Link IE
controller network uses
two-core cables, loopback is
performed even if a
disconnection or error is
detected on one side.
SW0095 to
SW0098
Reverse loop status of each
station
SW0080
OUT-side loopback station
No.
SW0099
Loopback station (forward loop
side)
SW0070
IN-side loopback station No.
SW009A
Loopback station (reverse loop
side)
SW0080
OUT-side loopback station
No.
SW009C to
SW009F
Loop usage status of each
station
SW0070
IN-side loopback station No.
(Content
changed)
Although the CC-Link IE
controller network uses
two-core cables, loopback is
performed even if a
disconnection or error is
detected on one side.
SW0071
IN-side loopback factor
SW0080
OUT-side loopback station
No.
SW0081
OUT-side loopback factor
SW00A8
Online test execution item/
faulty station (requesting side)
—
—
(Content
changed)
• Delete the sequence
program for the
corresponding part.
• The result of a test can be
checked by CC IE Control
Network Diagnostics in the
CC-Link IE controller
network module.
SW00A9
Online test result (requesting
side)
—
—
SW00AA
Online test execution item
(responding side)
—
—
SW00AB
Online test result (responding
side)
—
—
SW00AC
Offline test execution item/
faulty station (requesting side)
—
—
—
Delete the sequence program
for the corresponding part.
SW00AD
Offline test result (requesting
side)
—
—
SW00AE
Offline test execution item
(responding side)
—
—
SW00AF
Offline test result (responding
side)
—
—
SW00B0 to
SW00B3
Multiplex transmission status
(1)
—
—
SW00B4 to
SW00B7
Multiplex transmission status
(2)
—
—
Table App.26 Comparison of link special register (SW) (Continued)
MELSECNET/H
CC-Link IE controller network
Compatibility
Precautions for replacement
No.
Name
No.
Name
Содержание QJ71GP21-SX