6
- 19
6.3 Network Range Assignment
6.3.2 LX/LY settings
6
PARAMETER SETTING
(2) Using equal assignment
The link device I/O range can be equally assigned between the I/O master and other
stations. (LX/LY settings (1) only)
(a) Clicking
in [Assignment the CC IE Control network range] will display
the [Equal assignment] dialog box.
Set the following items and click
.
(Example) When assigning an LX/LY range of 1000 to 15FF (1536 points) equally
to the I/O range between the I/O master station and station No.2 to No.4
(b) Equal assignment is done in [LX/LY settings (1)] of [Assignment the CC IE Control
network range].
Figure 6.13 [Equal assignment] dialog box
Table 6.12 Setting items in the [Equal assignment] dialog box
Item
Description
X/Y equal
assignment
Start station
Set the start station.
(Setting range for Universal model QCPU: 1 to 120, Default: None)
(Setting range for other than Universal model QCPU: 1 to 64, Default: None)
End station
Set the end station.
(Setting range for Universal model QCPU: 1 to 120, Default: None)
(Setting range for other than Universal model QCPU: 1 to 64, Default: None)
Start No.
Set the start number of the LX/LY for equal assignment.
(Setting range: 0000
H
to 1FF0
H
, Default: None)
Total points
assigned
Set the total points of LX/LY, which are to be assigned equally.
(Setting range: 16 to 8192, Default: None)