APPENDICES
Appendix 1 Link Special Relay (SB) List
App
- 7
9
DE
DICA
T
E
D
INS
T
RUCT
IONS
10
T
R
OUB
L
E
S
HO
OT
IN
G
APPENDI
CES
INDEX
SB0052
Cyclic transmission stop
accept status (system)
Turned ON when stop request of cyclic transmission due to System link stop
(SB0003) is received.
OFF: Not received (SB0003 is OFF)
ON: Stop received (SB0003 is ON)
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error is held.
SB0053
Cyclic transmission stop
completion status
(system)
Turned ON when Cyclic transmission stop accept status (system)(SB0052) is
turned ON and cyclic transmission stop is completed.
OFF: Stop uncompleted (SB0003 is OFF)
ON: Stop completed (SB0003 is ON)
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error is held.
SB0054
Parameter receive
status
Stores the status of receiving parameters.
The parameter receive status from the CPU module is stored for the control
station.
The parameter receive status from the control station is stored for the normal
station.
OFF: Receive completed
ON: Receive uncompleted
SB0055
Received parameter
error
Stores the status of received parameter (Own parameter status is stored for
the control station)
OFF: Parameter normal
ON: Parameter error
SB0056
Communication status
Stores the transient transmission status.
OFF: Transient transmission by control station
ON: Transient transmission by sub-control station
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error is held.
SB005B
Own station's CPU
RUN status
Stores the RUN status of the CPU module of the own station.
OFF: RUN, STEP-RUN
ON: The CPU module stop due to STOP, PAUSE, or error
SB005C
I/O master station
(block 1)
Stores the I/O master station setting status of block 1.
OFF: No setting
ON: Setting set
When the setting is set, the station No. is stored into I/O master station (block
1) (SW005C).
(Condition)
• Valid when Data link status of own station (SB0049) is OFF.
Table App.2 Link special relay (SB) list (Continued)
No.
Name
Description
Availability
Control
station
Normal
station
Link special relay (SB): SB0052 to SB005C