App
- 62
Appendix 4 Comparison between CC-Link IE controller network and MELSECNET/H
Appendix 4.3 Link special relays (SB) and link special registers (SW)
APPENDICES
SW00B8
UNDER on the forward loop
side/coaxial bus UNDER
SW0068
SW0069
IN-side line error occurrence
rate (Max.)
IN-side line error occurrence
rate (present.)
(Content
changed)
• These operations in the
MELSECNET/H can be
substituted by IN-side line
error occurrence rate in the
CC-Link IE controller
network module.
• The station No. for the
station that receives an error
frame at IN-side can be
checked by SW0120 to
SW0127 and SW0140 to
SW0147.
SW00B9
CRC on the forward loop side/
coaxial bus CRC
SW00BA
OVER on the forward loop
side/coaxial bus OVER
SW00BB
Short frame on the forward
loop side/coaxial bus short
frame
SW00BC
Abort on the forward loop side
(AB,IF)/coaxial bus abort
(AB,IF)
SW00BD
Timeout on the forward loop
side (TIME)/ coaxial bus
timeout (TIME)
SW00BE
Receiving 2k bytes or more on
forward loop side (DATA)/
coaxial bus receiving 2k bytes
or more (DATA)
SW00BF
DPLL error on the forward loop
side/coaxial bus DPLL error
SW00C0
UNDER on the reverse loop
side
SW006A
SW006B
OUT-side line error
occurrence rate (Max.)
OUT-side line error
occurrence rate (present.)
(Content
changed)
• These operations in the
MELSECNET/H can be
substituted by OUT-side line
error occurrence rate in the
CC-Link IE controller
network module.
• The station No. for the
station that receives an error
frame at OUT-side can be
checked by SW0130 to
SW0137 and SW0150 to
SW0157.
SW00C1
CRC on the reverse loop side
SW00C2
OVER on the reverse loop
side
SW00C3
Short frame on the reverse
loop side
SW00C4
Abort on the reverse loop side
(AB, IF)
SW00C5
Timeout on the reverse loop
side (TIME)
SW00C6
Receiving 2k bytes or more on
reverse loop side (DATA)
SW00C7
DPLL error on reverse loop
side
SW00C8
Number of retries on the
forward loop side/ coaxial bus
retries error
SW0068
SW0069
IN-side line error occurrence
rate (Max.)
IN-side line error occurrence
rate (present.)
(Content
changed)
• This operation in the
MELSECNET/H can be
substituted by IN-side line
error occurrence rate in the
CC-Link IE controller
network module.
• The station No. for the
station that receives an error
frame at IN-side can be
checked by SW0120 to
SW0127 and SW0140 to
SW0147.
Table App.26 Comparison of link special register (SW) (Continued)
MELSECNET/H
CC-Link IE controller network
Compatibility
Precautions for replacement
No.
Name
No.
Name
Содержание QJ71GP21-SX
Страница 1: ......
Страница 2: ......
Страница 644: ...App 94 Appendix 6 External Dimensions Appendix 6 2 QJ71GP21S SX APPENDICES Memo ...
Страница 649: ......
Страница 650: ......