App
- 60
Appendix 4 Comparison between CC-Link IE controller network and MELSECNET/H
Appendix 4.3 Link special relays (SB) and link special registers (SW)
APPENDICES
SW0055
Parameter setting status
SW0055
Parameter setting status
None
SW0056
Current control station
SW0056
Current control station
Current remote master station
—
SW0057
Designated control station
SW0057
Designated control station
Designated remote master
station
—
SW0059
Total number of link stations
SW0059
Total number of link stations
SW005A
Maximum baton pass station
SW005A
Maximum baton pass station
SW005B
Maximum cyclic transmission
station
SW005B
Maximum cyclic
transmission station
SW005C
I/O master station (Block 1)
SW005C
I/O master station (Block 1)
SW005D
I/O master station (Block 2)
SW005D
I/O master station (Block 2)
SW0064 to
SW0067
Reserved station designation
SW00C0 to
SW00C7
Reserved station
specification
(No. changed)
SW0068
Communication mode
SW0063
Communication mode
(No. changed)
SW006B
Maximum link scan time
SW0060
Maximum link scan time
(No. changed)
• The same value is stored in
the control station and the
normal station in the CC-Link
IE controller network
module.
• The value to be stored is an
actual measurement value of
the link scan time.
• When setting a constant link
scan, the setting value of the
constant link scan is stored.
• When an actual
measurement value of the
link scan time is larger than a
setting value of the constant
link scan, the actual
measurement value of the
link scan time is stored.
SW006C
Minimum link scan time
SW0061
Minimum link scan time
(No. changed)
SW006D
Current link scan time
SW0062
Current link scan time
(No. changed)
SW006E
Low-speed cyclic scan time
—
—
—
Delete the sequence program
for the corresponding part.
SW0070 to
SW0073
Baton pass status of each
station
SW00A0 to
SW00A7
Baton pass status of each
station
(No. changed)
None
SW0074 to
SW0077
Cyclic transmission status of
each station
SW00B0 to
SW00B7
Cyclic transmission status of
each station
SW0078 to
SW007B
Parameter communication
status of each station
SW00D0 to
SW00D7
Parameter communication
status of each station
SW007C to
SW007F
Parameter error status of each
station
SW00E0 to
SW00E7
Parameter error status of
each station
SW0080 to
SW0083
CPU operation status of each
station (1)
SW0100 to
SW0107
CPU operation status of
each station (1)
SW0084 to
SW0087
CPU RUN status of each
station
SW00F0 to
SW00F7
CPU RUN status of each
station
SW0088 to
SW008B
CPU operation status of each
station (2)
SW0110 to
SW0117
CPU operation status of
each station (2)
SW008C to
SW008F
Power supply status of each
station
SW0180 to
SW0187
Power supply status of each
station
Table App.26 Comparison of link special register (SW) (Continued)
MELSECNET/H
CC-Link IE controller network
Compatibility
Precautions for replacement
No.
Name
No.
Name