App
- 54
Appendix 4 Comparison between CC-Link IE controller network and MELSECNET/H
Appendix 4.3 Link special relays (SB) and link special registers (SW)
APPENDICES
SB0070
Baton pass status of each
station
SB00A0
Baton pass status of each
station
(No. changed)
None
SB0071
Baton pass status of the
remote master station
—
—
—
Delete the sequence program
for the corresponding part.
SB0072
Remote sub-master station
transient transmission status
—
—
SB0074
Cyclic transmission status of
each station
SB00B0
Cyclic transmission status of
each station
(No. changed)
None
SB0075
Cyclic transmission status of
the remote master station
—
—
—
Delete the sequence program
for the corresponding part.
SB0076
Remote sub-master station
cyclic transmission status
—
—
SB0077
Remote sub-master station
cyclic transmission control
status
—
—
SB0078
Parameter communication
status of each station
SB00D0
Parameter communication
status of each station
(No. changed)
None
SB007A to
SB007B
Low-speed cyclic
communication status
—
—
—
Delete the sequence program
for the corresponding part.
SB007C
Parameter status of each
station
SB00E0
Parameter status of each
station
(No. changed)
None
SB0080
CPU operation status of each
station (1)
SB0100
CPU operation status of each
station (1)
SB0084
CPU RUN status of each
station
SB00F0
CPU RUN status of each
station
SB0085
CPU RUN status of the remote
master station
—
—
—
Delete the sequence program
for the corresponding part.
SB0086
Remote sub-master station
CPU RUN status
—
—
SB0088
CPU operation status of each
station (2)
SB0110
CPU operation status of each
station (2)
(No. changed)
None
SB008C
External power supply
information
SB0180
External power supply
information
(No. changed)
None
SB008D
Module type of each station
—
—
—
Delete the sequence program
for the corresponding part.
SB0090
Host loop status
SB0064
Own station's loop status
(No. changed)
None
SB0091
Forward loop status
SB0065
Loopback status
(No. changed)
• Although the CC-Link IE
controller network uses
two-core cables, loopbback is
performed even if a
disconnection or error is
detected on one side.
• The cause of loopback can be
checked by Own station's
loop status (SW0064).
SB0092
Forward loop status of the
remote master station
—
—
—
Delete the sequence program
for the corresponding part.
Table App.24 Comparison of link special relay (SB) (Continued)
MELSECNET/H
CC-Link IE controller network
Compatibility
Precautions for replacement
No.
Name
No.
Name