9
- 96
9.10 JP/GP.RECV
9
DEDICATED INSTRUCTIONS
(2) Control data
Table 9.54 Control data
Device
Item
Setting data
Setting range
Setting
side
*1
(S1)+0
Error completion
type
1) Error completion type (bit 7)
Specify the clock data setup status for error completion.
0: Clock data at the time of error completion is not set in the area
starting from (S1)+11.
1: Clock data at the time of error completion is set in the area
starting from (S1)+11.
0000
H
0080
H
User
(S1)+1
Completion status
The instruction completion status is stored.
0: Normal
Other than 0: Error (
—
System
(S1)+2
Own station
channel
Specify the channel of the own station, where receive data are stored.
(
Section 9.2.2 (1) When executing multiple link dedicated
instructions at the same time)
1 to 8
User
(S1)+3
Channel used by
sending station
Stores the channel used by the sending station.
1 to 8: Channel
—
System
(S1)+4
Network No. of
sending station
Stores network No. of the sending station.
1 to 239: Network No.
—
System
(S1)+5
Sending station
No.
Stores station No. of the sending station.
1 to 120: Station No.
—
System
(S1)+6
—
Unused
0
User
(S1)+7
—
Unused
0
User
(S1)+8
Arrival monitoring
time
Specify the monitoring time required for instruction completion.
If not completed within the time, the instruction is terminated with an
error.
0: 10 seconds
1 to 32767: 1 to 32767 seconds
0 to 32767
User
(S1)+9
Receive data
length
Stores the receive data size stored in (D1) to (D2)+n.
1 to 960: Receive data size (words)
—
System
(S1)+10
—
Unused
0
User
(S1)+11
Clock set flag
*2
The valid or invalid status of the data in the area starting from (S1)+12
is stored.
0: Invalid
1: Valid
—
System
(S1)+12
to
(S1)+15
Clock data on error
completion
*2
Clock data on error completion are stored in BCD format.
—
System
(S1)+16
Error-detected
network No.
*2
Network No. of the station, where an error was detected, is stored.
(However, when an error is detected at the own station, the network
No. is not stored.)
1 to 239: Network No.
—
System
b15
0
0
1)
b7
to
b0
to
(S1)+12
(S1)+13
(S1)+14
(S1)+15
Month (01
H
to 12
H
)
Hour (00
H
to 23
H
)
Second (00
H
to 59
H
)
Day (01
H
to 31
H
)
Minute (00
H
to 59
H
)
00
H
(Sun.) to 06
H
(Sat.)
Day of week (00
H
to 06
H
)
Year (00
H
to 99
H
), First 2 digits
Year (00
H
to 99
H
), Last 2 digits
b15
b8 b7
to
b0
to
Содержание QJ71GP21-SX
Страница 1: ......
Страница 2: ......
Страница 644: ...App 94 Appendix 6 External Dimensions Appendix 6 2 QJ71GP21S SX APPENDICES Memo ...
Страница 649: ......
Страница 650: ......