10
- 20
10.2 Error Code List
10
TROUBLESHOOTING
E262
H
Arrival confirmation error
(Dedicated instruction)
In all stations or group designation,
the dedicated instruction was
executed "with arrival confirmation"
set for the execution type.
For the REQ instruction, the set
request type is not correct.
• Change the execution type in the control data to
"No arrival confirmation", and retry the
operation.
• For the REQ instruction, check the request type
in the request data, and retry it.
• If the error persists even after taking the above
action, please consult your local Mitsubishi
representative.
E263
H
Network module error
The hardware has failed.
• Please consult your local Mitsubishi
representative.
E264
H
Transmission completion wait
time timeout error (Dedicated
instruction)
Timeout has occurred without
transmission completion.
• Check the network status in the CC IE Control
Network Diagnostics.
• If the error persists even after taking the above
action, please consult your local Mitsubishi
representative.
E265
H
Response timer timeout error
(Dedicated instruction)
Timeout has occurred without
response reception.
• Check the network status in the CC IE Control
Network Diagnostics.
• Check the version of the CC-Link IE controller
network compatible device on the target station.
• If the error persists even after taking the above
action, please consult your local Mitsubishi
representative.
A CC-Link dedicated instruction was
executed to a station that does not
support CC-Link dedicated
instructions.
E266
H
Unsupported request
reception error (Dedicated
instruction)
The SEND instruction was received
from any other station.
• Change the target station at the station where
the SEND instruction was executed.
• If the error persists even after taking the above
action, please consult your local Mitsubishi
representative.
E267
H
Target station No. error
(Dedicated instruction)
The own station No. was set as the
target station No.
• Confirm the target station No. in the control data,
and retry the operation.
• If the error persists even after taking the above
action, please consult your local Mitsubishi
representative.
E268
H
Execution/abnormal
completion type error
(Dedicated instruction)
The execution/abnormal completion
type was not set correctly.
• Confirm the execution/abnormal completion type
in the control data, and retry the operation.
• If the error persists even after taking the above
action, please consult your local Mitsubishi
representative.
E269
H
Request or sub-request type
error (REQ instruction)
The request or sub-request type of
the REQ instruction is not set
correctly.
• Check the request or sub-request type in the
request data, and retry the instruction.
• If the error persists even after taking the above
action, please consult your local Mitsubishi
representative.
E26A
H
No assign/present control
station (Dedicated instruction)
When there was no control station on
the network, the dedicated
instruction was executed with an
"assign or present control station"
specified.
• Confirm the target station No. in the control data,
and retry the operation.
• If the error persists even after taking the above
action, please consult your local Mitsubishi
representative.
E26B
H
Dedicated instruction
execution mode error
The dedicated instruction was
executed in circuit test mode.
• Change the circuit test mode of the control
station to online mode, and retry the operation.
• If the error persists even after taking the above
action, please consult your local Mitsubishi
representative.
Table 10.1 Error Code List (Continued)
Error code
Error
Error detail
Corrective action