9
- 160
9.17 Z(P).RTMWR
9
DEDICATED INSTRUCTIONS
(5) Program example
In the following example program, when M141 turns ON, clock data (08:30:00) is
written to all stations of network No.1.
(a) System configuration example
(b) Devices used in the program example
1) Special relay (SM), link special relay (SB), and link special register (SW)
Remark
For details about link special relay (SB) and link special register (SW), refer to the
following.
•Appendix 1 Link Special Relay (SB) List
•Appendix 2 Link Special Register (SW) List
2) Devices used by the user
Figure 9.136 System configuration example
Table 9.93 Special relay (SM), link special relay (SB), and link special register (SW)
Device
Description
Device
Description
SM400
Always ON
SB00A0
Baton pass status of each station
SB0047
Baton pass status (own station)
SW0034
Send/receive instruction (5) processing result
Table 9.94 Devices used by the user
Device
Description
Device
Description
M140
Clock data setting command
M146
Completion status indication device
M141
Start contact
D330 to
D334
Clock data
M145
Completion device
D608
Error code storage device
CPU module
RTMWR
RTMWR
instruction
request
target
(Target station)
RTMWR
instruction
request
target
(Target station)
RTMWR
instruction
request
target
(Target station)
RTMWR
instruction
request
source
(Own station)
CC-Link IE
controller
network module
Channel 5
CPU module
CC-Link IE
controller
network module
CPU module
CC-Link IE
controller
network module
CPU module
CC-Link IE
controller
network module
Network No.1
Station No.1
Station No.2
Station No.4
Station No.3
Clock data
writing
(8:30:00)
Clock data
writing
(8:30:00)
Clock data
writing
(8:30:00)