1
- 3
1.1 Features
1
OVERVIEW
(b) Since a large number of modules and link points can be used in one network, a
large-scale network system can be constructed.
Also, when expanding the network, additional stations and send points can be
easily set up.
* 1 A Universal model QCPU can be set to station No.1 to 120.
Any other than Universal model QCPUs can be set to station No.1 to 64.
* 2 A Basic model QCPU or safety CPU operates as a normal station. (It cannot be set to a control
station.)
* 3 For a Basic model QCPU or safety CPU, the link relay (LB) is 16K points (16384 points, 2KB) and
the link register (LW) is 16K points (16384 points, 32KB).
(c) High-speed data communications are available at the speed of 1Gbps.
Because the link scan time and transmission delay time are short, applications for
production of a short takt time can be built.
(Example) Link scan time in the case where the number of stations in the network
is 32
Figure 1.3 Number of stations per network
Figure 1.4 Maximum link points per network
Figure 1.5 High-speed data communications
When control station is
Universal model QCPU
When control station is
other than Universal model QCPU
120 (Control station:1, Normal station: 119 *1)
64 (Control station: 1, Normal station: 63)*2
Link relay (LB)
Link register (LW)
Link input (LX)
Link output (LY)
8K points (8192 points, 1KB)
8K points (8192 points, 1KB)
32K points (32768 points, 4KB)*3
128K points (131072 points, 256KB)*3
1
2
4
8
16
32
64
128
0
40
0
80
120
160
MELSECNET/10 (10Mbps)
MELSECNET/H (25Mbps)
CC-Link IE controller network (1Gbps)
Link scan time [ms]
Link points per network [K bytes]
Approx.
1/14
Approx.
1/30