Appendix 4.1 Comparison of specifications
The following describes the comparison of specifications between the CC-Link IE
controller network and the MELSECNET/H.
(1) Comparison of performance specifications
The transmission of the CC-Link IE controller network is made by the optical loop
system only.
When the coaxial bus system is used in the MELSECNET/H, consider to replace it
with an optical loop system.
The following shows the comparison of optical loop systems in the CC-Link IE
controller network and the MELSECNET/H.
Table App.11 Comparison of performance specifications
Item
CC-Link IE controller network
MELSECNET/H
Maximum
link points
per network
LB
32K points (32768 points, 4K bytes)
(16K points (16384 points, 2K bytes) for Basic
model QCPU or safety CPU)
16K points (16384 points, 2K bytes)
LW
128K points (131072 points, 256K bytes)
(16K points (16384 points, 32K bytes) for Basic
model QCPU or safety CPU)
16K points (16384 points, 32K bytes)
LX
8K points (8192 points, 1K byte)
LY
8K points (8192 points, 1K byte)
Maximum
link points
per station
LB
16K points (16384 points, 2K bytes)
• For MELSECNET/H or MELSECNET/10 mode,
{(LY + LB) 8 + (2 × LW)} 2000 bytes
• For MELSECNET/H extension mode,
{(LY + LB) 8 + (2 × LW)} 35840 bytes
LW
16K points (16384 points, 32K bytes)
LX
8K points (8192 points, 1K byte)
LY
8K points (8192 points, 1K byte)
Transient transmission capacity
Max. 1920 bytes
Communication speed
1Gbps
25Mbps/10Mbps
Number of stations per network
• When Universal model QCPU is used for control
station: 120 (Control station: 1, Normal station:
119)
• When other than Universal model QCPUs is
used for control station: 64 (Control station: 1,
Normal station: 63)
64 stations (Control station: 1, normal station: 63)
connection cable
Optical fiber cable (Multi-mode fiber)
(
Section 2.2.1 Order of optical fiber cables
(Optional))
Optical fiber cables used for MELSECNET/H
cannot be used.
Optical fiber cable
Overall cable distance
66000m (When connecting 120 stations)
30000m
Station-to-station distance (Max.)
550m (Core/Clad = 50/125 ( m))
200m to 2km (Depending on cable to be used and
communication speed)