9
- 22
9.4 JP/GP.SREAD
9
DEDICATED INSTRUCTIONS
(1) Setting data
* 1 Local devices and file registers for each program cannot be used as devices in setting data.
Table 9.13 Setting data
Setting data
*1
Description
Data type
Jn
Network No. of the own station (1 to 239, 254)
254: The network specified in Valid module during other station access
Binary 16 bits
Un
Start I/O number of the own station's CC-Link IE controller network module
(00 to FE
H
: The higher two digits of the 3-digit I/O number)
(S1)
Start device of the own station that stores control data
(
Device name
(S2)
Target station's start device where data to be read are stored
(D1)
The own station's start device where readout data will be stored
(A contiguous area for the read data length is required.)
(D2)
The own station's device that is turned on for one scan upon completion of the
instruction
(D2)+1 also turns ON if the instruction execution has failed.
Bit
(D3)
The target station's device that is turned on for one scan upon completion of the
instruction. (The target station can recognize that data have been read out with the
SREAD instruction.)