TROUBLESHOOTING
E251
H
Duplicated dedicated
instruction reception error
Transient data for the same
dedicated instruction have been
received two times or more.
• Check the network status in the CC IE Control
Network Diagnostics.
E252
H
Network module error
The hardware has failed.
• Please consult your local Mitsubishi
representative.
E253
H
E254
H
Target station CPU type error
(Dedicated instruction)
The target station CPU type setting
is not correct.
• Confirm the target station CPU type in the
control data, and retry the operation.
• If the error persists even after taking the above
action, please consult your local Mitsubishi
representative.
E255
H
Data size error (Dedicated
instruction)
The data length setting is not correct.
• Confirm the data length in the control data, and
retry the operation.
• If the error persists even after taking the above
action, please consult your local Mitsubishi
representative.
E256
H
Arrival monitoring time
specification error (Dedicated
instruction)
The arrival monitoring time was not
specified correctly.
• Confirm the arrival monitoring time in the control
data, and retry the operation.
• If the error persists even after taking the above
action, please consult your local Mitsubishi
representative.
E257
H
Resend count specification
error (Dedicated instruction)
The number of resends was not set
correctly.
• Confirm the number of resends in the control
data, and retry the operation.
• If the error persists even after taking the above
action, please consult your local Mitsubishi
representative.
E258
H
Target network No. error
(Dedicated instruction)
The target network No. was not set
correctly.
• Confirm the target network No. in the control
station, and retry the operation.
• If the error persists even after taking the above
action, please consult your local Mitsubishi
representative.
E259
H
Target station channel error
(SEND instruction)
Target station channel is not set
correctly for the SEND instruction.
• Check the Target station channel in the control
data, and then retry the instruction.
• If the error persists even after taking the above
action, please consult your local Mitsubishi
representative.
E25A
H
Modification specification error
(UINI instruction)
Modification specification is not set
correctly for the UINI instruction.
• Check the Modification specification in the
control data, and then retry the instruction.
• If the error persists even after taking the above
action, please consult your local Mitsubishi
representative.
E25B
H
Own station No. error (UINI
instruction)
Incorrect own station No. is set for
the UINI instruction.
• Check the own station No. set in the control
data, and then retry the instruction.
• If the error persists even after taking the above
action, please consult your local Mitsubishi
representative.
E25C
H
to
E261
H
Network module error
The hardware has failed.
• Please consult your local Mitsubishi
representative.
Table 10.1 Error Code List (Continued)