Managing Data Calls
Setting up DEFINITY LAN Gateway
Administrator’s Guide for Avaya Communication Manager
455
November 2003
Setting up DEFINITY LAN Gateway
Before you start
This section describes pre-administrative tasks associated with the Co-Resident DLG.
For S8100 Media Server Configurations
If you want to use a TN799 C-LAN circuit pack as the Ethernet Interface for the Co-Resident DLG,
proceed as follows:
1
Type display system-parameters customer-options and press
ENTER
.
2
Go to page 2 and make sure the
ASAI Link Core Capabilities
and/or
Computer Telephony
Adjunct Links
fields are y, and the
Co-Res DEFINITY LAN Gateway
field is y.
3
Type display node-names ip and press
ENTER
.
Make sure that there is a node name associated with the C-LAN. If there is not a node name, add
one.
4
Type display ip-interfaces and press
ENTER
.
Make sure the C-LAN is administered and its Ethernet port is enabled. If the C-LAN is not listed
(the Type field should display
C-LAN
, and the previously administered node name should appear
in the Node Name / Local Node field), add a C-LAN.
5
Type list data-module and press
ENTER
.
Make sure that the Ethernet port on the C-LAN is administered. If the Ethernet port is not listed,
add it with the
add data-module
command (the
Service Type
field should be Ethernet and the
Port
field should be port 17 on the TN799).
If you want to use a TN2314 circuit pack as the Ethernet Interface for the Co-Resident DLG, proceed as
follows:
1
Type display system-parameters customer-options and press
ENTER
.
2
Go to page 2 and make sure the
ASAI Link Core Capabilities
and/or
Computer Telephony
Adjunct Links
fields are y, and the
Co-Res DEFINITY LAN Gateway
field is y.
3
Go to page 4 and make sure that the
Processor Ethernet
field is y.
4
Type display ip-interfaces and press
ENTER
.
Make sure the PROCR is administered and its Ethernet port is enabled. If the PROCR is not listed
(PROCR should appear in the Type field and the previously administered node name should
appear in the Node Name field), add a PROCR.
For S8300 Media Server
Although the S8300 Media Server does not use a standard DEFINITY server port board, the
pre-administration is the same.
1
Type display system-parameters customer-options and press
ENTER
.
2
Go to page 2 and make sure the
ASAI Link Core Capabilities
and/or
Computer Telephony
Adjunct Links
fields are y, and the
Co-Res DEFINITY LAN Gateway
field is y.
Содержание Communication Manager
Страница 320: ...Setting Up Telecommuting Training Users 320 Administrator s Guide for Avaya Communication Manager November 2003...
Страница 416: ...Managing Group Communications Observing Calls 416 Administrator s Guide for Avaya Communication Manager November 2003...
Страница 502: ...Administering Media Servers SNMP Agents 502 Administrator s Guide for Avaya Communication Manager November 2003...
Страница 602: ...Phone Reference Internet Protocol IP Softphones 602 Administrator s Guide for Avaya Communication Manager November 2003...
Страница 1338: ...Screen Reference Vector Directory Number 1338 Administrator s Guide for Avaya Communication Manager November 2003...
Страница 1832: ...Glossary and Abbreviations Z 1832 Administrator s Guide for Avaya Communication Manager November 2003...
Страница 1854: ...Index X 1854 Administrator s Guide for Avaya Communication Manager November 2003...