Screen Reference
Trunk Group
Administrator’s Guide for Avaya Communication Manager
1289
November 2003
Version
Use this field to adjust the signaling on multi-country CO trunk circuit packs. Entries in this field adjust
signaling characteristics on these circuit packs to match the signaling characteristics of the public
network in a specific country. The field appears only for CO, FX, and WATS trunk groups when the
Country field is 5, 16, or 23.
Wink Timer (msec)
This field allows you to reduce the risk of glare by controlling part of call setup. Requirements for the
United States domestic network specify that the wink signal for wink-start trunks must begin within 5
seconds after a trunk is seized. For trunks with a delay-dial start, the wink must not last longer than 5
seconds. While some circuit packs are hard-coded to allow the full 5 seconds in both cases, other circuit
packs allow you reduce the allowed start time and duration, thus reducing the window in which glare
could occur.
Unlike other fields on this screen, the
Wink Timer
field therefore controls 2 different variables. What
your entry does depends on the outgoing value in the
Trunk Type (in/out)
field.
.
Valid entries
Usage
If the
Country
field is 5, the Version field only controls TN2147 ports.
a
Enter a to use standard signaling for the Netherlands public
network.
b
Enter b to use country 1 (U.S.) signaling. The value b is appropriate
if Communication Manager is connected to a central office using an
Ericcson AXE-10 switch.
If the Country field is 16 or 23, the Version field sets the input impedance value and
only controls TN465C (vintage 2 or later) ports.
a Enter
a to set input impedance to 600 Ohms.
b
Enter b to set input impedance to 900 Ohms. The value b is
appropriate in Brazil.
Setting of the Trunk
Type (in/out) field
What the Wink Timer field sets
…/wink
Maximum duration of the wink signal
(wait-for-wink-to-end)
…/delay
Maximum interval after trunk seizure for the wink to begin
(wait-for-wink-to-start)
Содержание Communication Manager
Страница 320: ...Setting Up Telecommuting Training Users 320 Administrator s Guide for Avaya Communication Manager November 2003...
Страница 416: ...Managing Group Communications Observing Calls 416 Administrator s Guide for Avaya Communication Manager November 2003...
Страница 502: ...Administering Media Servers SNMP Agents 502 Administrator s Guide for Avaya Communication Manager November 2003...
Страница 602: ...Phone Reference Internet Protocol IP Softphones 602 Administrator s Guide for Avaya Communication Manager November 2003...
Страница 1338: ...Screen Reference Vector Directory Number 1338 Administrator s Guide for Avaya Communication Manager November 2003...
Страница 1832: ...Glossary and Abbreviations Z 1832 Administrator s Guide for Avaya Communication Manager November 2003...
Страница 1854: ...Index X 1854 Administrator s Guide for Avaya Communication Manager November 2003...