C613-50170-01 Rev B
Command Reference for x510 Series
746
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
P
OWER
OVER
E
THERNET
C
OMMANDS
SHOW
POWER
-
INLINE
INTERFACE
Related
Commands
show power-inline interface detail
Pri
The current PoE priorities for PoE ports on the PSE, as configured
from a
command:
•
Low
displays when the
low
parameter is issued. The lowest
priority for a PoE enabled port (default).
•
High
displays when the
high
parameter is issued. The
second highest priority for a PoE enabled port.
•
Crit
displays when the
critical
parameter is issued. The
highest priority for a PoE enabled port.
Oper
The current PoE port state when this command was issued:
•
Powered
displays if there is a PD connected and power is
being supplied.
•
Denied
displays if supplying power would make the switch
go over the power budget.
•
Off
displays if the port is not supplying power but has not
been denied power by the switch. This is the default state for
ports that are not connected to a PD.
•
Disabled
displays if the PoE port is administratively disabled.
•
Syncing
displays if PoE is still initializing the port when you
issue the command.
•
Fault
displays if there is a problem with PoE on the port.
•
Unknown
displays if PoE cannot determine the state of the
port.
Power
The power consumption in milliwatts (mW) for the PoE port
when this command was entered.
Device
The description of the connected PD device if a description has
been added with the
command. No
description is shown for PDs not configured with the
command.
Class
The class of the connected PD, if power is being supplied to the
PD from the PSE.
See the
PoE Feature Overview and Configuration Guide
for
further information about power classes.
Max (mW)
The power in milliwatts (mW) allocated for the PoE port.
Additionally, note the following is displayed per PoE port:
•
[U]
if the power limit for a port was user configured (with the
•
[L]
if the power limit for a port was supplied by LLDP.
•
[C]
if the power limit for a port was supplied by the PD class.
Table 3:
Parameters in
show power-inline interface
output (cont.)
Parameter
Description