C613-50170-01 Rev B
Command Reference for x510 Series
2775
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
T
RIGGER
C
OMMANDS
TYPE
TIME
type time
Overview
This command configures a trigger that activates at a specified time of day.
Syntax
type time <
hh:mm
>
Mode
Trigger Configuration
Usage
A combined limit of 10 triggers of the type time and type periodic can be
configured. If you attempt to add more than 10 triggers the following error
message is displayed:
Example
To configure trigger
86
to activate at
15:53
, use the following commands:
awplus#
configure terminal
awplus(config)#
trigger 86
awplus(config-trigger)#
type time 15:53
Related
Commands
Parameter
Description
<
hh:mm
>
The time to activate the trigger.
% Cannot configure more than 10 triggers with the type time or
periodic