C613-50170-01 Rev B
Command Reference for x510 Series
2164
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
E
THERNET
P
ROTECTION
S
WITCHED
R
ING
(EPSR
ING
™) C
OMMANDS
SHOW
EPSR
NOTE
:
Running your switch as an EPSR master node requires a feature license.
Output:
superloop
topology
The following examples show the output display for superloop topology network.
NOTE
:
Running your switch as an EPSR master node requires a feature license.
Table 2:
Example output from the
show epsr
command run on a master node
EPSR Information
------------------------------------------------------------
Name ........................ test4
Mode .......................... Master
Status ........................ Enabled
State ......................... Complete
Control Vlan .................. 4
Data VLAN(s) .................. 20
Interface Mode ................ Ports Only
Primary Port .................. port1.0.3
Primary Port Status ........... Forwarding
Secondary Port ................ port1.0.4
Secondary Port Status ......... Forwarding
Hello Time .................... 1 s
Failover Time ................. 2 s
Ring Flap Time ................ 0 s
Trap .......................... Enabled
Enhanced Recovery ............. Disabled
------------------------------------------------------------
Table 3:
Example output from the
show epsr
command run on a Master Node
EPSR Information
------------------------------------------------------------
Name ........................ test4
Mode .......................... Master
Status ........................ Enabled
State ......................... Complete
Control Vlan .................. 4
Data VLAN(s) .................. 20
Interface Mode ................ Ports Only
Primary Port .................. port1.0.3
Status ...................... Forwarding (logically blocking)
Is On Common Segment ........ No
Blocking Control ............ Physical
Secondary Port ................ port1.0.4
Status ...................... Blocked
Is On Common Segment ........ No
Blocking Control ............ Physical
Hello Time .................... 1 s
Failover Time ................. 2 s
Ring Flap Time ................ 0 s
Trap .......................... Enabled
Enhanced Recovery ............. Disabled
SLP Priority .................. 12
------------------------------------------------------------